Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

NIST Bullet Signature Measurement System for RM (Reference Material) 8240 Standard Bullets

Published

Author(s)

Li Ma, Jun-Feng Song, Eric P. Whitenton, Theodore V. Vorburger, J Zhou, A Zheng

Abstract

A bullet signature measurement system based on a stylus instrument was developed at the National Institute of Standards and Technology (NIST) for the signature measurements of NIST Rm (Reference Material) 8240 standard bullets. The standard bullets are developed as a reference standard for bullet signature measurements and are aimed to support the recently established National Integrated Ballistics Information Network (NIBIN) by the Bureau of Alcohol, Tobacco and Firearms (ATF) and the Federal Bureau of Investigation (FBI). The RM bullets are designed as both a virtual and a physical bullet signature standard. The virtual standard is a set of six digitized bullet signature originally profiled from six master bullets fired at ATF and FBI using six different guns. By using the virtual signature standard to control the tool path on a numerically controlled diamond turning machine at NIST, 40 RM bullets were produced. In this paper, a comparison parameter and an algorithm using auto-and cross-correlation functions are described for qualifying the buller signature differences between the RM bullets and the virtual bullet signature standard. When two compared signatures are exactly the same (point by point), their cross-correlation function (CCF) valuable will be equal to 100%. The measurement system setup, measurement program, and initial measurement results are discussed. Initial measurement results for the 10 standard bullets, each measured at six land impressions, show that the CCF values for the 240 signature measurements are higher than 95%, with most of them even higher than 99%. These results demonstrate the high reproducibility for both the manufacturing process and the measurement system for the NIST RM 8240 standard bullets.
Citation
Journal of Forensic Sciences
Volume
49(4)
Issue
No. 4

Keywords

ballistics measurements, bullet signature, CCF, cross-correlation function, forensic science, reference material, RM, standard bullet

Citation

Ma, L. , Song, J. , Whitenton, E. , Vorburger, T. , Zhou, J. and Zheng, A. (2004), NIST Bullet Signature Measurement System for RM (Reference Material) 8240 Standard Bullets, Journal of Forensic Sciences (Accessed April 19, 2024)
Created June 30, 2004, Updated October 12, 2021