Measurement Techniques and Results of an Intercomparison of Horn Antenna Gain in IEC-R 320 at Frequencies of 26.5, 33.0 and 40.0 GHz

Published

Author(s)

David Gentle, A. Beardmore, J. Achkar, J Park, Katherine MacReynolds, Jan P. deVreede

Abstract

A measurement comparison of the boresight gain of two IEC-R320 horn antennas has been carried out between five national metrology laboratories at 26.5, 33 and 40 GHz. The following five national metrology laboratories participated: NPL (United Kingdom), NMI-VSL (The Netherlands) NIST (United States of America), BNM-LCIE (France) and KRISS (Republic of Korea). The National Physical Laboratory (United Kingdom) acted as the pilot laboratory for the comparison.
Citation
CCEM Key Comparison CCEM.RF-K3.F (GT-RF 92-1)

Keywords

antenna gain comparison, pyramidal horn antenna, thermistor sensor

Citation

Gentle, D. , Beardmore, A. , Achkar, J. , Park, J. , MacReynolds, K. and deVreede, J. (2003), Measurement Techniques and Results of an Intercomparison of Horn Antenna Gain in IEC-R 320 at Frequencies of 26.5, 33.0 and 40.0 GHz, CCEM Key Comparison CCEM.RF-K3.F (GT-RF 92-1) (Accessed October 4, 2024)