An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
Measurement and Analysis of Results Obtained on Biological Substances With D.S.C.
Published
Author(s)
H J. Hinz, Frederick P. Schwarz
Abstract
Differential scanning calorimeters (DSCs) have been widely used to determine the thermodynamics of phase transitions and conformational changes in biological systems including proteins, nucleic acid sequences, and lipid assemblies. DSCs monitor the temperature difference between two vessels, one containing the biological solution and the other containing a reference solution, as a function of temperature at a given scan rate. Recommendations for DSC measurement procedures, calibration procedures, and procedures for testing the performance of the DSC are described. Analysis of the measurements should include a correction for the time response of the instrument and conversion of the power vs. time curve to heat capacity vs. temperature plot. Thermodynamic transition models should only be applied to the analysis of the heat capacity curves if the model-derived transition temperatures and enthalpies are independent of the DSC scan rate. Otherwise, kinetic models should be applied to the analysis of data. Application of thermodynamic transition models involving two states, two states and dissociation, and three states to the heat capacity vs. temperature data are described. To check the operating performance with standard DSCs, samples of 1 to 10 mg mL-1 solutions of hen egg white lysozyme in 0.1 M HC1-glycine buffer at pH = 2.4 0.1 were sent to six different DSC laboratories worldwide. The values obtained from proper measurements and application of a two-state transition model yielded an average unfolding transition temperature for lysozyme of 331.2 K with values ranging from 329.4 to 331.9 K, and an average transition enthalpy of 405 kJ mol-1 with values ranging from 377 to 439 kJ mol-1. It is recommended that the reporting of DSC results be specific with regard to the composition of the solution, the operating conditions and calibrations of the DSC determination of base lines that may be model-dependent, and the model used in the analysis of the data.
Citation
Journal of Chemical Thermodynamics
Volume
33
Issue
11
Pub Type
Journals
Keywords
biological, calorimetry, different scanning calorimetry, phase transitions, temperature, thermodynamics
Hinz, H.
and Schwarz, F.
(2001),
Measurement and Analysis of Results Obtained on Biological Substances With D.S.C., Journal of Chemical Thermodynamics
(Accessed October 14, 2024)