Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

International Interlaboratory Comparison of Mixtures of Polystyrenes With Different End Groups Obtained by Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF-MS): Preliminary Results

Published

Author(s)

Charles M. Guttman, S Wetzel, Kathleen M. Flynn, B M. Fanconi, William E. Wallace, David L. VanderHart

Abstract

NIST has sponsored a MALDI-TOF-MS interlaboratory comparison of mixtures of polymers of the same repeat unit with closely matching molecular masses but with different end groups. This interlaboratory comparison was designed to see how well a group of labs from all over the world could get agreement on the percentages of each polymer that they found in a mixture of these polymers. In an earlier Interlaboratory Comparision , NIST studied the MMD and the moments of these on a PS and compared the results with classical methods.1 Polystyrenes of a molecular mass around 9000 with two different end groups were used. The Polystyrenes were both initiated with butyl initiator. One was terminated with an H (PSH) and the other was terminated with a CH2CH2OH (PSOH). Five mixtures of these were made up with mass ratios between approximately 95:5 to 10:90 PSOH: PSH. Samples of these mixtures were sent to any institution requesting it. A total of 14 institutions participated.
Proceedings Title
ASMS Confrence on Mass Spectrometry and Allied Topics | 52nd | Proceedings of the 52nd ASMS Confrence on Mass Spectrometry and Allied Topics | American Society for Mass Spectrometry (ASMS)
Volume
33(1)
Conference Dates
May 23-27, 2004
Conference Location
Nashville, TN
Conference Title
ASMS Conference on Mass Spectrometry

Keywords

functionalized polymers, interlaboratory comparison, polymer end groups, polymer mixtures, quantitative mass spectrometry

Citation

Guttman, C. , Wetzel, S. , Flynn, K. , Fanconi, B. , Wallace, W. and VanderHart, D. (2004), International Interlaboratory Comparison of Mixtures of Polystyrenes With Different End Groups Obtained by Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF-MS): Preliminary Results, ASMS Confrence on Mass Spectrometry and Allied Topics | 52nd | Proceedings of the 52nd ASMS Confrence on Mass Spectrometry and Allied Topics | American Society for Mass Spectrometry (ASMS), Nashville, TN, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=852364 (Accessed October 15, 2024)

Issues

If you have any questions about this publication or are having problems accessing it, please contact reflib@nist.gov.