Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Digital phantom for time-domain near-infrared spectroscopy of tissue: Concept and proof-of-principle experiments

Published

Author(s)

Heidrun Wabnitz, Lin Yang, Rainer Macdonald, Jeeseong C. Hwang

Abstract

In the clinically relevant field of tissue oximetry, there is an urgent need to develop phantom-based methods for validation. Physical phantom approaches based on solid or liquid turbid media containing hemoglobin with variable oxygenation have limited capabilities to represent real tissues regarding optical properties, structure and variability. Digital phantoms are an alternative with high flexibility. Rather than physically simulating the process of light propagation, they provide the detector with light signals mimicking the signals detected in vivo. We present a technique to produce digital phantoms for time-domain diffuse optical spectroscopy that mimic arbitrary photon time-of- flight distributions (DTOFs) by creating a time-dependent attenuation. The setup contains a spatial light modulator (SLM) and a set of optical fibers of different lengths corresponding to a stepwise delay. The light pulse entering the arrangement is spatially dispersed and illuminates the SLM which controls the intensity at each pixel. The SLM array is imaged onto the entrance faces of the array of delay fibers. In this way, the amount of photons received by each individual fiber can be adjusted. Finally, the light transmitted through all fibers are combined and fed to the detector of the time-domain instrument under test. In this way, DTOFs of any desired shape can be obtained. For first proof-of-principle experiments to demonstrate the general feasibility of the concept we used a liquid-crystal SLM and a set of four graded-index fibers differing in length by about 100 mm. The tests were performed with a time-domain instrument based on time- correlated single photon counting, with picosecond diode and supercontinuum laser sources and a single-photon avalanche diode as well as a hybrid photomultiplier as detectors. This large separation in fiber lengths allowed the performance regarding amplitude and temporal shape to be assessed for each delay independently.
Citation
SPIE Conference Proceedings
Volume
10870

Keywords

tissue-simulating phantoms, validation, tissue oximetry, time-domain diffuse optical spectroscopy, time-of-flight distribution, spatial light modulator

Citation

Wabnitz, H. , Yang, L. , Macdonald, R. and Hwang, J. (2019), Digital phantom for time-domain near-infrared spectroscopy of tissue: Concept and proof-of-principle experiments, SPIE Conference Proceedings (Accessed April 24, 2024)
Created February 26, 2019, Updated October 12, 2021