Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Apparatus for Wide-Ranging, High-Accuracy Fluid p-ρ-T Measurements Based on a Compact Two-Sinker Densimeter

Published

Author(s)

Mark O. McLinden, Cornelia Losch-Will

Abstract

An apparatus for high-accuracy fluid p-ρ-T measurements over wide ranges of temperature, pressure, and density (90 to 520 K; 0 to 40 MPa; 5 to 1700 kg/m3) is described. The densimeter is based on the Archimedes (buoyancy) principle and is a two-sinker system incorporating a magnetic suspension coupling. The density is obtained directly, without the need for calibration fluids. The complete apparatus, including the thermostat, pressure and temperature measuring systems, auxiliary systems, and computer control, is described. The determination of the sinker volumes and calibrations of the measuring systems are detailed. The traceability to national standards and fundamental SI quantities is emphasized. The uncertainty (k = 2) in density is {plus or minus}(0.0025 % + 0.0006 kg/m3) at 293 K and 0.1 MPa. The uncertainty increases to {plus or minus}(0.015 % + 0.001 kg/m3) at the upper and lower temperature limits of the apparatus and a pressure of 40 MPa, primarily due to increased uncertainties in the sinker volumes. The uncertainty in temperature is {plus or minus} 0.004 K and that in pressure ranges from {plus or minus} 0.005 % to 0.05 %. Results for high-purity nitrogen and helium demonstrate the performance of the densimeter and confirm the stated uncertainties. New data are presented for a high-density fluoroether; these measurements demonstrate the capabilities for liquids.
Citation
Journal of Chemical Thermodynamics
Volume
39

Keywords

2-trifluoromethyl-3-ethoxydodecafluorohexane, densimeter, experimental measurements, helium, nitrogen, pressure-density-temperature behavior, thermodynamic properties, two-sinker densimeter, virial coefficients

Citation

McLinden, M. and Losch-Will, C. (2006), Apparatus for Wide-Ranging, High-Accuracy Fluid p-ρ-T Measurements Based on a Compact Two-Sinker Densimeter, Journal of Chemical Thermodynamics, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=50300 (Accessed December 10, 2024)

Issues

If you have any questions about this publication or are having problems accessing it, please contact reflib@nist.gov.

Created September 28, 2006, Updated February 19, 2017