Below is an example of a Meta TEDS:
|
|
|
|
| |
| |
|
Meta TEDS |
|
|
| Field # |
Description |
Field Length (Bytes) |
Field Type |
Field Contents |
| Data Structure related information |
|
|
|
| 1 |
Meta-TEDS Length |
4 |
U32 |
48 |
| 2 |
IEEE 1451 Standards Family Working Group Number |
1 |
U8 |
2 |
| 3 |
TEDS Major Version Number |
2 |
U16 |
2 |
| 4 |
Future Extensions Key |
1 |
U8 |
0 (NONE) |
| 5 |
CHANNEL_ZERO Industry Extensions Key |
1 |
U8 |
0 (NONE) |
| 6 |
End User's Application Specific TEDS Key |
1 |
U8 |
0 |
| 7 |
Number of Implemented Channels |
1 |
U8 |
1 |
| 8 |
String Language Code |
1 |
U8 |
0 |
| 9 |
Bytes per Character |
1 |
U8 |
1 |
| Timing Related information |
|
|
|
| 10 |
Worst Case Channel Data Model Length |
1 |
U8 |
2 |
| 11 |
Worst Case Channel Data Repetitions |
2 |
U16 |
1 |
| 12 |
Worst Case Channel Update Time |
4 |
F32 |
2.00E-05 |
| 13 |
Worst Case Channel Write Setup Time |
4 |
F32 |
0 |
| 14 |
Worst Case Channel Read Setup Time |
4 |
F32 |
8.00E-05 |
| 15 |
Input/Output Response Time |
4 |
F32 |
5.00E-04 |
| 16 |
Calibration TEDS Write Time |
4 |
F32 |
0.00E+00 |
| 17 |
Worst Case Data Clock Frequency |
4 |
U32 |
2.00E+05 |
| 18 |
Worst Case Channel Sampling Period |
4 |
F32 |
2.00E-04 |
| 19 |
Worst Case Unit Warm Up Time |
4 |
F32 |
1 |
| Channel grouping related information |
|
|
|
| 20 |
Channel Groupings Data Sub-Block Length |
2 |
U16 |
0 |
| 21 |
Number of Channel Groupings = G |
0 |
U8 |
- |
| 22 |
Group Name Length |
0 |
U8 |
- |
| 23 |
Group Name (<=255) |
0 |
STRING |
- |
| 24 |
Group Type |
0 |
U8 |
- |
| 25 |
Number of Group Members = N |
0 |
U8 |
- |
| 26 |
Member Channel Numbers List = M(N) (<=255) |
0 |
array of U8 |
- |
| Data integrity information |
|
|
|
| 27 |
Checksum for Meta-TEDS |
2 |
U16 |
62856 |
| Data Structure related information |
|
|
|
| 28 |
Meta-Identification TEDS Length |
4 |
U32 |
310 |
| Identification related information |
|
|
|
| 29 |
Manufacturer's Identification Length |
1 |
U8 |
55 |
| 30 |
Manufacturer's Identification (<=255) |
55 |
STRING |
Texas Instruments Incorporated Control Product Division |
| 31 |
Model Number Length |
1 |
U8 |
9 |
| 32 |
Model Number (<=255) |
9 |
STRING |
EX3514.XX |
| 33 |
Revision Code Length |
1 |
U8 |
2 |
| 34 |
Revision Code |
2 |
STRING |
01 |
| 35 |
Serial Number Length |
1 |
U8 |
5 |
| 36 |
Serial Number (<=255) |
5 |
STRING |
SN-01 |
| 37 |
Data Code Length |
1 |
U8 |
25 |
| 38 |
Data Code (<=255) |
25 |
STRING |
November 1, 1995, Shift 1 |
| 39 |
Product Description Length |
2 |
U16 |
205 |
| 40 |
Product Description (<=65535) |
205 |
STRING |
Description: Ratio metric Pressure Transducer |
| |
|
|
|
Part Number: EX3514.XX |
| |
|
|
|
Serial Number: SN-01 |
| |
|
|
|
Pressure Range: 0 to 3000 PSIA |
| |
|
|
|
Input Voltage: 5Vdc |
| |
|
|
|
Output Voltage 0 to 5 Vdc |
| |
|
|
|
Temperature Range: -40 To 85 degrees C |
| |
|
|
|
|
| Data Integrity information data sub-block |
|
|
|
| 41 |
Checksum for Meta-Identification TEDS |
2 |
U16 |
38702 |
| |
| Back to TEDS |
|