1. A Dosimetric Uncertainty Analysis for Photon-Emitting Brachytherapy Sources: Report of the AAPM Task Group No. 138 and GEC-ESTRO
Published: 2/1/2011
Authors: Larry A DeWerd, Geoffrey S Ibbott, Ali S Meigooni, Michael G Mitch, Mark J Rivard, Kurt E Stump, Bruce R Thomadsen, Jack L. Venselaar
Abstract: This report addresses uncertainties pertaining to brachytherapy source dosimetry. The ISO Guide to the Expression of Uncertainty in Measurement (GUM) and the NIST Technical Note 1297 are taken as reference standards for uncertainty formalism. Uncer ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=904147

2. A Fibre Optic Dosimeter for Absorbed Dose Measurements of Low Energy X-Ray-Emitting Brachytherapy Sources,
Published: 1/1/2006
Authors: A P Sliski, Christopher Graham Soares, Michael G Mitch
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=103640

3. Encapsulation of ^u99m^Tc within Fullerenes: a Novel Radionuclidic Carrier
Published: 1/1/1997
Authors: Lisa R Karam, Michael G Mitch, Bert M Coursey
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=103192

4. Evaluation of the New Cesium-131 Seed for Use in Low-Energy X-Ray Brachytherapy
Published: 1/1/2004
Authors: M K Murphy, R K Piper, L R Greenwood, Michael G Mitch, P J. Lamperti, Stephen Michael Seltzer, M J Bales, M H Phillips
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=103264

5. High-resolution 3D dose distribution measured for two low-energy x-ray brachytherapy seeds: I125 and PD103
Published: 11/3/2010
Authors: Guerda Massillon, Ronaldo Minniti, Michael G Mitch, Christopher Graham Soares
Abstract: An investigation of the three-dimensional (3D) absorbed dose distribution around two low-energy photon (125I and 103Pd) brachytherapy seeds is presented. A high spatial resolution 3D gel scanning system has been utilized. The radial dose function, g( ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=901631

6. Mapping the Distribution of ^u90^Sr in Teeth with a Photostimulable Phosphor Imaging Detector
Published: 1/1/2002
Authors: A A Romanyukha, Michael G Mitch, Z-C Lin, V Yu Nagy, Bert M Coursey
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=103312

7. Measurement of the absorbed dose distribution near Ir192 intravascular brachytherapy seed using a high spatial resolution gel dosimetry system
Published: 5/10/2012
Authors: Ronaldo Minniti, G. Massillon, Michael G Mitch, Christopher Graham Soares
Abstract: The absorbed dose distribution at sub-millimeter distances from the Best single 192Ir intravascular brachytherapy seed was measured using a high spatial resolution gel dosimetry system. Two gel phantoms from the same batch were used; one for the seed ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=908738

8. New National Air-Kerma-Strength Standards for ^u125^I and ^u103^Pd Brachytherapy Seeds
Published: 1/1/2003
Authors: Stephen Michael Seltzer, P J. Lamperti, R Loevinger, Michael G Mitch, J T Weaver, Bert M Coursey
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=103633

9. Primary Standards and Dosimetry Protocols for Brachytherapy Sources
Published: 3/20/2009
Authors: Christopher Graham Soares, G. Douyssey, Michael G Mitch
Abstract: Current primary standards for the calibration of both photon and beta particle emitting brachythrapy sources are reviewed.  Methods for quality control being used as well as methods of transferring these standards to secondary laboratories and u ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=842434

10. Primary Standards for Brachytherapy Sources
Published: 6/1/2009
Authors: Michael G Mitch, Christopher Graham Soares
Abstract: The AAPM dosimetry protocol for LDR brachytherapy seeds that emit x-rays of energies ≤ 50 keV is described in the TG-43U1 report (Rivard et al. 2004). In this protocol, it is specified that the strength of such sources be expressed in terms of ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=901166



Search NIST-wide:


(Search abstract and keywords)


Last Name:
First Name:







Special Publications:

Looking for a NIST Special Publication (NIST SP Series)? Place the series number and dash in the report number field (Example: 800-) and begin your search.

  • SP 250-XX: Calibration Services
  • SP 260-XX: Standard Reference Materials
  • SP 300-XX: Precision Measurement and Calibration
  • SP 400-XX: Semiconductor Measurement Technology
  • SP 480-XX: Law Enforcement Technology
  • SP 500-XX: Computer Systems Technology
  • SP 700-XX: Industrial Measurement Series
  • SP 800-XX: Computer Security Series
  • SP 823-XX: Integrated Services Digital Network Series