1. Normalized Performance Parameters for a Residential Heat Pump in the Cooling Mode with Single Faults Imposed
Published: 3/3/2014
Authors: William V Payne, Jin Min Cho, Piotr A Domanski
Abstract: The performance of a residential split heat pump in the cooling mode operating under nine faults was described using normalized performance parameters determined from a ratio of the faulty value to the no-fault value obtained from heat pump tests in ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=910617

2. Application of a Linear Fit Rating Method for Mixed Single-Speed Unitary Air Conditioners
Published: 1/28/2013
Authors: William V Payne, Piotr A Domanski
Abstract: A method employing the simultaneous solution of two linear fits is used to determine the rated cooling capacity and seasonal energy efficiency ratio, SEER, of outdoor unit and indoor unit air-conditioner combinations not previously tested as a comple ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=911575

3. FDD CX: A Fault Detection and Diagnostic Commissioning Tool for Residential Air Conditioners and Heat Pumps
Series: Technical Note (NIST TN)
Report Number: 1774
Published: 11/21/2012
Authors: William V Payne, Jae Hyeok Heo, Piotr A Domanski
Abstract: FDD CX is a commissioning tool for unitary, air-source, single-speed, vapor compression air conditioner (AC) or heat pump (HP) systems. This software tool can be utilized to commission the operation of residential ACs or HPs to ensure proper ref ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=912311

4. Residential Heat Pump Heating Performance with Single Faults Imposed
Published: 10/29/2010
Authors: William V Payne, Piotr A Domanski, Seok Ho Yoon
Abstract: A heat pump equipped with a thermostatic expansion valve (TXV) was tested in environmental chambers during steady-state no-fault and imposed-fault operation. The studied system was an R410A split residential heat pump with an 8.8 kW nominal cooling ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=906002

5. Residential Heat Pump Heating Performance with Single Faults Imposed
Published: 7/11/2010
Authors: Seok Ho Yoon, William V Payne, Piotr A Domanski
Abstract: A heat pump equipped with a thermostatic expansion valve (TXV) was tested in environmental chambers during steady-state no-fault and imposed-fault operation. The studied system was an R410A split residential heat pump with an 8.8 kW nominal cooling ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=905484

6. Development and Verification of a Linear-Fit Mixed System Rating Method for Unitary Two-Speed and Variable-Speed Air Conditioners
Series: Technical Note (NIST TN)
Report Number: 1667
Published: 6/7/2010
Author: William V Payne
Abstract: A linear-fit method of rating residential-type air conditioning systems was evaluated based on performance predictions and laboratory testing of one two-speed matched system and two mixed systems (matched two-speed condensing unit, matched indoor coi ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=905434

7. Development of the Reference Model for a Residential Heat Pump System for Cooling Mode Fault Detection and Diagnosis
Published: 4/2/2010
Authors: M Kim, Seok H. Yoon, Piotr A Domanski, William V Payne
Abstract: Development of a reference model to predict the value of system parameters during fault free operation is a basic step for fault detection and diagnosis (FDD). In order to develop an accurate and effective reference model of a heat pump system, expe ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=861053

8. Heating Mode Performance Measurements For A Residential Heat Pump With Single-Faults Imposed
Series: Technical Note (NIST TN)
Report Number: 1648
Published: 9/30/2009
Authors: William V Payne, Piotr A Domanski, Seok Ho Yoon
Abstract: The objective of this research was to acquire heating mode experimental data for a residential heat pump needed for the development of a FDD methodology. Within this project, a heat pump equipped with a thermostatic expansion valve (TXV) was tested ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=903554

9. Cooling Mode Fault Detection And Diagnosis Method For A Residential Heat Pump
Series: Special Publication (NIST SP)
Report Number: 1087
Published: 10/17/2008
Authors: Minsung Kim, Seok H. Yoon, William V Payne, Piotr A Domanski
Abstract: Performance characteristics of a R410A residential unitary split heat pump equipped with a thermostatic expansion valve (TXV) were investigated in the cooling mode under no-fault and faulty conditions. An automated method of steady-state detection w ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=861650

10. Design of a steady-state detector for fault detection and diagnosis of a residential air conditioner
Published: 5/1/2008
Authors: Minsung Kim, Seok H. Yoon, Piotr A Domanski, William V Payne
Abstract: This paper presents a general methodology for developing a steady-state detector for a vapor compression system based on a moving window and using standard deviations of seven measurements selected as features. The feature thresholds and optimized ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=861614



Search NIST-wide:


(Search abstract and keywords)


Last Name:
First Name:







Special Publications:

Looking for a NIST Special Publication (NIST SP Series)? Place the series number and dash in the report number field (Example: 800-) and begin your search.

  • SP 250-XX: Calibration Services
  • SP 260-XX: Standard Reference Materials
  • SP 300-XX: Precision Measurement and Calibration
  • SP 400-XX: Semiconductor Measurement Technology
  • SP 480-XX: Law Enforcement Technology
  • SP 500-XX: Computer Systems Technology
  • SP 700-XX: Industrial Measurement Series
  • SP 800-XX: Computer Security Series
  • SP 823-XX: Integrated Services Digital Network Series