NIST logo

Publications Portal

You searched on: Author: william payne

Displaying records 11 to 20 of 42 records.
Resort by: Date / Title


11. Development of the Reference Model for a Residential Heat Pump System for Cooling Mode Fault Detection and Diagnosis
Published: 4/2/2010
Authors: M Kim, Seok H. Yoon, Piotr A Domanski, William V Payne
Abstract: Development of a reference model to predict the value of system parameters during fault free operation is a basic step for fault detection and diagnosis (FDD). In order to develop an accurate and effective reference model of a heat pump system, expe ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=861053

12. Heating Mode Performance Measurements For A Residential Heat Pump With Single-Faults Imposed
Series: Technical Note (NIST TN)
Report Number: 1648
Published: 9/30/2009
Authors: William V Payne, Piotr A Domanski, Seok Ho Yoon
Abstract: The objective of this research was to acquire heating mode experimental data for a residential heat pump needed for the development of a FDD methodology. Within this project, a heat pump equipped with a thermostatic expansion valve (TXV) was tested ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=903554

13. Cooling Mode Fault Detection And Diagnosis Method For A Residential Heat Pump
Series: Special Publication (NIST SP)
Report Number: 1087
Published: 10/17/2008
Authors: Minsung Kim, Seok H. Yoon, William V Payne, Piotr A Domanski
Abstract: Performance characteristics of a R410A residential unitary split heat pump equipped with a thermostatic expansion valve (TXV) were investigated in the cooling mode under no-fault and faulty conditions. An automated method of steady-state detection w ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=861650

14. Design of a steady-state detector for fault detection and diagnosis of a residential air conditioner
Published: 5/1/2008
Authors: Minsung Kim, Seok H. Yoon, Piotr A Domanski, William V Payne
Abstract: This paper presents a general methodology for developing a steady-state detector for a vapor compression system based on a moving window and using standard deviations of seven measurements selected as features. The feature thresholds and optimized ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=861614

15. Longitudinal Heat Conduction in Finned-Tube Evaporators
Published: 8/21/2007
Authors: Piotr A Domanski, William V Payne, J M Choi
Abstract: The paper evaluates performance of finned-tube evaporators at different refrigerant exit superheats to assess the impact of longitudinal heat conduction on capacity.
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=861658

16. A Low Cost Digital Vibration Meter
Series: Journal of Research (NIST JRES)
Published: 4/1/2007
Authors: William V Payne, Jon Geist
Abstract: This report describes the development of a low cost vibration amplitude sensor. The processes used to develop this sensor involve the use of Micro-Electronic and Mechanical Systems (MEMS) manufacturing techniques. The major mechanical element of th ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=861030

17. Survey of HSPF and Heating Capacity Ratings for ICM Mixed Systems Relative to OEM Mixed Systems and Highest Sales Volume Tested Combinations
Published: 4/1/2007
Author: William V Payne
Abstract: This investigation compares the Heating Seasonal Performance Factor (HSPF) and the high temperature heating capacity (Q(47)) ratings of Independent Coil Manufacturers (ICMs) and Original Equipment Manufacturers (OEMs) to determine the distribution of ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=910373

18. Performance of a Residential Heat Pump Operating in the Cooling Mode With Single Faults Imposed
Published: 9/1/2006
Authors: William V Payne, Piotr A Domanski, Minsung Kim, Christian Hermes
Abstract: System behavior of a R410A residential unitary split heat pump system operating in the cooling mode was investigated. Seven artificial faults were implemented: compressor/reversing valve leakage, improper outdoor air flow, improper indoor air flow, ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=861036

19. Performance of a Residential Heat Pump Operating in the Cooling Mode with Single Faults Imposed (NISTIR 7350)
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 7350
Published: 9/1/2006
Authors: Minsung Kim, William V Payne, Piotr A Domanski, Christian Hermes
Abstract: System behavior of a R410A residential unitary split heat pump system was investigated. The system was operated in cooling mode and used a thermostatic expansion valve (TXV) as the refrigerant expansion device. Seven artificial faults were tested: co ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=910407

20. Survey of SEER Ratings for Independent Coil Manufacturer Mixed Systems Relative to Original Equipment Manufacturer Mixed Systems and Highest Sales Volume Tested Combinations
Published: 9/1/2006
Author: William V Payne
Abstract: This investigation compares the Seasonal Energy Efficiency Ratio (SEER) ratings of independent coil manufacturers (ICMs) and original equipment manufacturers (OEMs) to determine the distribution of mixed system SEER ratings provided by ICMs and OEMs. ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=910392



Search NIST-wide:


(Search abstract and keywords)


Last Name:
First Name:







Special Publications:

Looking for a NIST Special Publication (NIST SP Series)? Place the series number and dash in the report number field (Example: 800-) and begin your search.

  • SP 250-XX: Calibration Services
  • SP 260-XX: Standard Reference Materials
  • SP 300-XX: Precision Measurement and Calibration
  • SP 400-XX: Semiconductor Measurement Technology
  • SP 480-XX: Law Enforcement Technology
  • SP 500-XX: Computer Systems Technology
  • SP 700-XX: Industrial Measurement Series
  • SP 800-XX: Computer Security Series
  • SP 823-XX: Integrated Services Digital Network Series