Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Air Change Effectiveness Measurements in Two Modern Office Buildings

Published

Author(s)

Andrew K. Persily, William S. Dols, Steven J. Nabinger

Abstract

Local age of air and air change effectiveness were determined in two office buildings using tracer gas techniques to study the applicability of the associated measurement procedures in mechanically ventilated office buildings. Measurement issues examined include the establishment of a uniform tracer gas concentration at the start of the test and the relationship of ventilation system configuration and system operation to the test procedure. Air change effectiveness was determined at locations in the occupied space based on the local age of air at that location and the age of air in the corresponding ventilation system return duct. Values of the air change effectiveness in the occupied space were generally close to one, which is consistent with good mixing of the ventilation air within the occupied space. Deviations from 1.0, on the order of 10%, did occur, but given the limited experience with these measurement procedures in the field it is not clear whether these deviations are significant. These tests provide data on air change effectiveness to supplement the limited database on mechanically ventilated office buildings in the U.S. In addition, the experience obtained with the measurement procedures will assist in the development of a standardized approach to measuring air change effectiveness in the field.
Citation
Indoor Air
Publisher Info
, -1

Keywords

office buildings, air change effectiveness, building performance, commercial buildings, indoor air quality, mechanical ventilation, tracer gas, ventilation, ventilation effectiveness

Citation

Persily, A. , Dols, W. and Nabinger, S. (1994), Air Change Effectiveness Measurements in Two Modern Office Buildings, Indoor Air, , -1, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=916610 (Accessed April 25, 2024)
Created January 1, 1994, Updated February 17, 2017