NIST logo

Publication Citation: Long Term Air Quality Monitoring in a Net-Zero Energy Residential Test Facility Designed with Specifications for Low Emitting Interior Products

NIST Authors in Bold

Author(s): Dustin G. Poppendieck; Lisa C. Ng; Matthew P. Schlegel; Andrew K. Persily; Alfred Hodgson;
Title: Long Term Air Quality Monitoring in a Net-Zero Energy Residential Test Facility Designed with Specifications for Low Emitting Interior Products
Published: August 06, 2014
Abstract: This study evaluated the effectiveness of a low-VOC (volatile organic compounds) specification designed to minimize occupant exposures to indoor air pollutants in a net-zero energy research house meeting the ASHRAE Standard 62.2 ventilation requirements. The results show that the use of medium density fiberboard and particleboard with no-added formaldehyde resins for cabinetry and other finished products effectively controlled the formaldehyde emissions and kept concentrations below levels in typical new homes. Monitoring of seasonal indoor VOC concentrations suggests that building envelope components may be an overlooked source for some VOCs, especially aldehydes and alkanes.
Proceedings: 13th International Conference on Indoor Air Quality and Climate Conference
Location: Hong Kong, -1
Dates: July 7-12, 2014
Keywords: Formaldehyde, Low Energy, Residential, Indoor Air, VOCs
Research Areas: Indoor Air Quality, Building and Fire Research
PDF version: PDF Document Click here to retrieve PDF version of paper (498KB)