Publication Citation: Differential sampling measurement of a 7 V rms Sine Wave with a Programmable Josephson Voltage Standard

NIST Authors in Bold

Author(s): Alain Rufenacht; Charles J. Burroughs; Paul D. Dresselhaus; Samuel P. Benz;
Title: Differential sampling measurement of a 7 V rms Sine Wave with a Programmable Josephson Voltage Standard
Published: June 01, 2013
Abstract: A 10 V programmable Josephson voltage standard has enabled sine waves with voltages up to 7 V rms to be accurately measured with a differential sampling measurement technique. Expanding the voltage range for this technique enables direct calibration of the low-frequency ranges of commercial calibrators in the ac voltage mode. This paper reviews the practically achievable performance and challenges of the differential sampling measurement technique that arise when measuring rms voltages greater than a few volts. A relative uncertainty of 4 parts in 107 was achieved with the technique when measuring a 7 V rms sine wave generated by a calibrator at 62.5 Hz.
Citation: IEEE Transactions on Instrumentation and Measurement
Volume: 62
Issue: 6
Pages: pp. 1587 - 1593
Keywords: Digital-analog conversion; Josephson arrays; Quantization; Signal synthesis; Standards; Superconducting integrated circuits; Voltage measurement; Power Measurement
Research Areas: Electrical Quantities, Instrumentation, Superconductors, Quantum Devices, Superconducting Electronics, Quantum Electrical Measurements
DOI: http://dx.doi.org/10.1109/TIM.2013.2237993  (Note: May link to a non-U.S. Government webpage)
PDF version: PDF Document Click here to retrieve PDF version of paper (860KB)