NIST logo

Publication Citation: Pipe Flow Characteristics of Alternative Agent/Nitrogen Mixtures (NISTIR 5499)

NIST Authors in Bold

Author(s): Thomas G. Cleary; M D. King; Jiann C. Yang; William L. Grosshandler;
Title: Pipe Flow Characteristics of Alternative Agent/Nitrogen Mixtures (NISTIR 5499)
Published: September 01, 1994
Abstract: The evaluation of alternative agents for application in engine nacelle fire protection includes delivery efficiency of agent from a remote storge bottle through piping to the nacelle injection loacation. Present military requirements for halon systems specify a maximum discharge time from the remote bottle to the injection location of 1 second. A similar performance criterion for the replacement agent delivery will more than likely be required. The applicability of retro-fitting existing systems or optimal design of new systems necessitates a thorough understanding of the two-phase flow in piping. As part of the halon replacement project, an experimental pipe flow apparatus was constructed and is being used to examine alternative agent flow in various horizontal piping configurations and conditions. The selected agents for engine nacelle fire protection are CF3I, HFC-227ea, and HFC-125. Halon 1301 is included in this study in order to establish a reference for comparison.
Citation: NIST Interagency/Internal Report (NISTIR) - 5499
Keywords: fire research; pipes; nitrogen; nacelle fires; halons; fire suppression; fire extinguishing agents