NIST logo

Publication Citation: Comparisons of Soot Volume Fraction Measurements Using Optical and Isokinetic Sampling Techniques

NIST Authors in Bold

Author(s): M. Y. Choi; George W. Mulholland; Anthony P. Hamins; Takashi Kashiwagi;
Title: Comparisons of Soot Volume Fraction Measurements Using Optical and Isokinetic Sampling Techniques
Published: October 25, 1993
Abstract: In a previous study, the performance of a three-line optical probe technique for measuring soot volume fraction and temperature was assessed by conducting experiments in the path-invariant environment of a premixed flame. In that study, the temperature and soot volume fraction (fva, based on absorption measurements at 632.8 nm and fve, based on emission measurements at 900 nm and 1000 nm) measurements in a premixed ethylene/air flame were compared to the results of Harris and Weiner. Although the temperatures and mean soot volume fractions compared favorably, the discrepancy between fva and fve prompted new measurements to evaluate the importance of source wavelength on the fva measurements, scattering by soot particles, light absorption by 'large' molecules and the use of different indices of refraction reported in the literature.
Proceedings: Combustion Institute/Eastern States Section
Location: Princeton, NJ
Dates: October 25-28, 1993
Keywords: soot; optical measurement; volume fraction; sampling; experiments
Research Areas: Building and Fire Research
PDF version: PDF Document Click here to retrieve PDF version of paper (316KB)