NIST logo

Publication Citation: Bilateral comparison of power measurement standards for KrF lasers between PTB and NIST

NIST Authors in Bold

Author(s): Marla L. Dowell; Christopher L. Cromer; Darryl A. Keenan; Stefan Kuck; Friedhelm Brandt;
Title: Bilateral comparison of power measurement standards for KrF lasers between PTB and NIST
Published: May 02, 2010
Abstract: We report results of the first bilateral laser power comparison for 248-nm KrF excimer lasers accomplished by the National Metrology Institutes of Germany (Physikalisch-Technische Bundesanstalt, PTB) and of the United States of America (National Institute of Standards and Technology, NIST). Laser transfer standards for average power were calibrated at both laboratories. The average powers were between 0.5 W, 1 W and 2 W. At 248 nm, the relative agreement was between 1 x 10^-3 and 6 x 10^-3, which is well within the expanded uncertainty of the bilateral degree of equivalence of approximately 2 x 10^-2. Thus, this comparison confirms that the measurement procedures of both laboratories are consistent and the uncertainty budgets contain all significant contributions.
Citation: Journal of Metrology Society of India
Volume: 25
Issue: 1
Pages: pp. 37 - 45
Keywords: international comparison; laser metrology; laser power; radiometry
Research Areas: Optoelectronics