Publication Citation: Nondestructive 3D Evaluation of Microleakage Induced by Polymerization Shrinkage of Dental Composites

NIST Authors in Bold

Author(s): Jirun Sun; Naomi Eidelman; Sheng Lin-Gibson;
Title: Nondestructive 3D Evaluation of Microleakage Induced by Polymerization Shrinkage of Dental Composites
Published: January 05, 2009
Abstract: Microleakage induced by polymerization shrinkage in methacrylate based dental composites continues to be a major concern for dental restoratives. Current methods for characterizing microleakage lack quantification and fail to provide a comprehensive evaluation, thus hinders the development of solutions to resuce/prevent microleakage.This work demonstrates that X-ray microcomputed tomography ( CT) can be used to examine the position and volume of composites nondestructively and precisely. Two series of samples systematically varying in volume and configuration (C-factor) were evaluated to determine how these parameters affect the polymerization shrinkage and microleakage formation, where the shrinkage was calculated based on volume changes before and after polymerization and microleakage was determined based on volume changes as a function of position.Microleakage results obtained by CT were compared to dye penetration outcomes. Detail analysis procedures for these novel approaches, as well as factors that affect the shrinkage and microleakage, such as the volume and configuration of the samples, are discussed.
Citation: Biomaterials
Keywords: dental composite;microcomputed;microleakage polymerization;shrinkage;tomography;x-ray
Research Areas: Dental
PDF version: PDF Document Click here to retrieve PDF version of paper (1MB)