NIST logo

Publication Citation: Dynamic Force Measurement: Instrumented Charpy Impact Testing

NIST Authors in Bold

Author(s): Christopher N. McCowan; Jolene D. Splett; E. Lucon;
Title: Dynamic Force Measurement: Instrumented Charpy Impact Testing
Published: January 01, 2008
Abstract: The maximum forces measured by the machines in this round robin are in good agreement. This general result shows that the static force calibration of instrumented strikers is quite robust, and that the various striker designs evaluated here performed in a predictable manner. One machine in the round robin was identified as an outlier by the dynamic force measurement results, indicating that dynamic testing may be a useful approach to check the performance of the instrumented machine and measurement system.
Citation: NIST Interagency/Internal Report (NISTIR) - 6652
Issue: NISTIR 6652
Pages: pp. i - 28
Keywords: ;Charpy;dynamic force verification;impact testing;Instrumented Charpy
Research Areas: Materials Science
PDF version: PDF Document Click here to retrieve PDF version of paper (779KB)