61. Development of a High Flux Conduction Calibration Apparatus
Published: 12/31/1997
Authors: William L Grosshandler, David L. Blackburn
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=24758

62. Fire Suppression Efficiency Screening Method
Published: 12/3/1997
Authors: Jiann C Yang, Michelle K Donnelly, William L Grosshandler
Abstract: Most of the current methods for fire suppression efficiency screening (e.g., cup burners) are designed for screening agents that can be delivered in the form of vapor. The search for alternatives to halons for fire suppression applications has identi ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=911504

63. Evaporation of a Small Water Droplet Containing an Additive
Published: 8/1/1997
Authors: M D King, Jiann C Yang, W. S. Chien, William L Grosshandler
Abstract: An experimental study on the evaporation of a small water droplet containing an additive on a heated, polished stainless-steel surface was performed. Solutions of water containing 30% (w/w) and 60% (w/w) of potassium acetate and sodium iodide were us ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=911498

64. Test Fire Signatures and the Fire-Emulator/Detector-Evaluation (NISTIR 6030)
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 6030
Published: 6/1/1997
Authors: William L Grosshandler, Thomas George Cleary
Abstract: Existing methods for evaluating the performance of smoke and thermal detectors are reviewed. The levels of combustion gases, smoke, temperature and velocity likely to be produced in the European standard detector test fires are discussed, and this i ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=912276

65. Facility for Calibrating Heat Flu Sensors in a Convective Environment
Series: OTHER
Published: 1/1/1997
Authors: David G Holmberg, Kenneth David Steckler, C A. Womeldorf, William L Grosshandler
Abstract: The National Institute of Standards and Technology (NIST) presently conducts heat flux sensor calibrations using standard radiation methods. In practice, however, many heat flux sensors are used in test environments where convective heat transfer dom ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=910706

66. Simple Piezoelectric Droplet Generator
Published: 1/1/1997
Authors: Jiann C Yang, W. S. Chien, M D King, William L Grosshandler
Abstract: A design for a piezoelectric on-demand droplet generator is presented. Its simple construction and ease of operation distinguish this generator from other previously reported. The droplet generator has been successfully used to produce droplets of aq ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=911561

67. Aerosol and SPGG Technology Fire Suppression Screening Methods (NISTIR 5904)
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 5904
Published: 10/28/1996
Authors: William L Grosshandler, Jiann C Yang, Thomas George Cleary
Abstract: The search for alternatives to halons for fire suppression applications has identified not only new compounds which have physical properties similar to the bromochlorofluorocarbon family, but also inert gaseous agents that are released from a solid s ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=911308

68. Heat Flux Calibration Flow and Conduction Facilities: Status Report
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 5904
Published: 10/28/1996
Authors: Kenneth David Steckler, William L Grosshandler
Abstract: Standard methods exist at NIST for calibrating thermal radiation detectors up to 10 kW/m2 using blackbody caviies, and up to 40kW/m2 using a monochromatic laser source. Heat Flux transducers, however, are often used under conditions where convection ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=910707

69. Evaporation of a Small Aqueous Suppressing Agent Droplet (NISTIR 5904)
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 5904
Published: 10/1/1996
Authors: W. S. Chien, Jiann C Yang, M D King, William L Grosshandler
Abstract: Due to its ozone-depleting potential, halon 1301 (CF3Br) has been banned from production under the Montreal Protocol. The research for halon replacement(s) has led to the reconsideration of using water in certain applications. However, under cold sto ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=911497

70. Minimum Mass Flux Requirements to Suppress Burning Surfaces With Water Sprays (NISTIR 5795)
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 5795
Published: 4/1/1996
Authors: Jiann C Yang, C I Boyer, William L Grosshandler
Abstract: Experimental measurements of extinguishment times of burning solid fuels using water were conducted using a prototype micronozzle array and a piezoelectric droplet generator. Solid fuels considered included solid white pine, polymethylmethacrylate, a ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=911531



Search NIST-wide:


(Search abstract and keywords)


Last Name:
First Name:







Special Publications:

Looking for a NIST Special Publication (NIST SP Series)? Place the series number and dash in the report number field (Example: 800-) and begin your search.

  • SP 250-XX: Calibration Services
  • SP 260-XX: Standard Reference Materials
  • SP 300-XX: Precision Measurement and Calibration
  • SP 400-XX: Semiconductor Measurement Technology
  • SP 480-XX: Law Enforcement Technology
  • SP 500-XX: Computer Systems Technology
  • SP 700-XX: Industrial Measurement Series
  • SP 800-XX: Computer Security Series
  • SP 823-XX: Integrated Services Digital Network Series