Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications by: Joseph Fowler (Assoc)

Search Title, Abstract, Conference, Citation, Keyword or Author
Displaying 26 - 50 of 53

Approaches to the Optimal Nonlinear Analysis of Microcalorimeter Pulses

March 8, 2018
Author(s)
Joseph W. Fowler, Christine G. Pappas, Bradley K. Alpert, William B. Doriese, Galen C. O'Neil, Joel N. Ullom, Daniel S. Swetz
We consider how to analyze microcalorimeter pulses for quantities that are nonlinear in the data, while preserving the signal-to-noise advantages of linear optimal filtering. We apply the approach to compute the electrothermal feedback energy deficit (the

L-Edge Spectroscopy of Dilute, Radiation-Sensitive Systems Using a Transition-Edge-Sensor Array

December 7, 2017
Author(s)
Daniel S. Swetz, William B. Doriese, Joseph W. Fowler, Johnathon D. Gard, Gene C. Hilton, Kelsey M. Morgan, Galen C. O'Neil, Joel N. Ullom
We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition- edge-sensor (TES)

Simultaneous readout of 128 X-ray and Gamma-ray Transition-edge Microcalorimeters using Microwave SQUID Multiplexing

August 8, 2017
Author(s)
John Mates, Dan Becker, Douglas Bennett, Johnathon Gard, James P. Hays-Wehle, Joseph Fowler, Gene C. Hilton, Carl D. Reintsema, Dan Schmidt, Daniel Swetz, Leila R. Vale, Joel Ullom
The number of elements in most cryogenic sensor arrays is limited by the technology available to multiplex signals from the array into a smaller number of wires and readout amplifiers. The largest demonstrated arrays of transition-edge sensor (TES)

A Reassessment of Absolute Energies of X-ray L Lines of Lanthanide Metals

June 28, 2017
Author(s)
Bradley Alpert, W.Bertrand (Randy) Doriese, Gene C. Hilton, Lawrence T. Hudson, Young I. Joe, Kelsey Morgan, Carl D. Reintsema, Dan Schmidt, Daniel Swetz, Csilla Szabo-Foster, Joel Ullom, Joseph Fowler, Galen O'Neil, Douglas Bennett
We introduce a new technique for determining x-ray fluorescence line energies and widths, and we present measurements made with this technique of 22 x-ray L lines from lanthanide-series elements. The technique uses arrays of transition-edge sensors

Counting Near Infrared Photons with Microwave Kinetic Inductance Detectors

May 22, 2017
Author(s)
Jiansong Gao, Michael R. Vissers, Joel N. Ullom, Johannes Hubmayr, Joseph W. Fowler, Leila R. Vale, Weijie Guo
We demonstrate photon counting at 1550~nm wavelength using microwave kinetic inductance detectors (MKIDs) made from TiN/Ti/TiN trilayer films with superconducting transition temperature $T_{c} \sim$ 1.4~K. The detector has a lump-element design with a

A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science

May 16, 2017
Author(s)
William B. Doriese, Peter Abbamonte, Douglas A. Bennett, Edward V. Denison, Yizhi Fang, Daniel A. Fischer, Colin P. Fitzgerald, Joseph W. Fowler, Johnathon D. Gard, Gene C. Hilton, Cherno Jaye, Jessica L. McChesney, Luis Miaja Avila, Kelsey M. Morgan, Young Il Joe, Galen C. O'Neil, Carl D. Reintsema, Fanny Rodolakis, Daniel R. Schmidt, Hideyuki Tatsuno, Jens Uhlig, Leila R. Vale, Joel N. Ullom, Daniel S. Swetz
We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more

Ultrafast time-resolved x-ray absorption spectroscopy of ferrioxalate photolysis with a laser plasma x-ray source and microcalorimeter array

February 17, 2017
Author(s)
Galen C. O'Neil, Joel N. Ullom, Luis Miaja Avila, Young Il Joe, Joseph W. Fowler, Carl D. Reintsema, Daniel S. Swetz, Kevin L. Silverman, Daniel R. Schmidt, Bruce D. Ravel, Gene C. Hilton, William B. Doriese, Bradley K. Alpert, Ralph Jimenez
Using a table-top apparatus based upon a laser plasma x-ray source and an array of cryogenic microcalorimeter x-ray detectors, we have measured the transient x-ray absorption spectrum during the ferrioxalate photoreduction reaction. We observe the Fe K

When "Optimal Filtering" Isn't

December 7, 2016
Author(s)
Joseph Fowler, Bradley Alpert, W.Bertrand (Randy) Doriese, James P. Hays-Wehle, Young I. Joe, Kelsey Morgan, Galen O'Neil, Joel Ullom, Dan Schmidt, Daniel Swetz
The so-called ''optimal filter'' analysis of a microcalorimeter's x-ray pulses is statistically optimal only if all pulses have the same shape, regardless of energy. The shapes of pulses from a nonlinear detector can and do depend on the pulse energy

First application of superconducting transition-edge-sensor microcalorimeters to hadronic-atom x-ray spectroscopy

September 30, 2016
Author(s)
Douglas Bennett, W.Bertrand (Randy) Doriese, Joseph Fowler, Johnathon Gard, James P. Hays-Wehle, Gene C. Hilton, Carl D. Reintsema, Daniel Swetz, Joel Ullom
High-resolution pionic-atom x-ray spectroscopy was performed with an x-ray spectrometer based on a 240-pixel array of superconducting transition-edge-sensor (TES)microcalorimeters at the πM1 beam line of the Paul Scherrer Institute. The pionic-carbon 4 → 3

Ultrafast time-resolved hard x-ray emission spectroscopy on a table top

September 27, 2016
Author(s)
Luis Miaja Avila, Galen C. O'Neil, Young Il Joe, Bradley K. Alpert, Niels Damrauer, William B. Doriese, Steven Fatur, Joseph W. Fowler, Gene C. Hilton, Ralph Jimenez, Carl D. Reintsema, Daniel R. Schmidt, Kevin L. Silverman, Daniel S. Swetz, Hideyuki Tatsuno, Joel N. Ullom
Chemical reactions driven by light are fundamental to biology and a source of inspiration for engineering materials to perform tasks such as solar energy harvesting and data storage. Observing and understanding photodynamics requires experimental tools

Code-division-multiplexed readout of large arrays of TES microcalorimeters

September 15, 2016
Author(s)
Kelsey M. Morgan, Bradley K. Alpert, Douglas A. Bennett, William B. Doriese, Joseph W. Fowler, Johnathon D. Gard, Gene C. Hilton, Kent D. Irwin, Young Il Joe, Galen C. O'Neil, Carl D. Reintsema, Edward V. Denison, Daniel R. Schmidt, Joel N. Ullom, Daniel S. Swetz
Code-division multiplexing (CDM) offers a path to reading out large arrays of transition edge sensor (TES) X-ray micro-calorimeters with excellent energy and timing resolution. We demonstrate the readout of X-ray TESs with a 32-channel flux-summed code

Absolute Energy Calibration of X-ray TESs with 0.04 eV Uncertainty at 6.4 keV in a Hadron-Beam Environment

January 19, 2016
Author(s)
Hideyuki Tatsuno, William B. Doriese, Douglas A. Bennett, Catalina Curceanu, Joseph W. Fowler, Johnathon D. Gard, Fredrick P. Gustafsson, Tadashi Hashimoto, Ryugo S. Hayano, James P. Hays-Wehle, Gene C. Hilton, Mihail Iliescu, Shigeru Ishimoto, Kenta Itahashi, Masashiko Iwasaki, Keisuke Kuwabara, Yue Ma, Johann Marton, Hirofumi Noda, Galen C. O'Neil, Shinji Okada, Haruhiko Outa, Carl D. Reintsema, Masaharu Sato, Daniel R. Schmidt, Hexi Shi, Ken Suzuki, Takatoshi Suzuki, Jens Uhlig, Joel N. Ullom, Eberhard Widmann, Shinya Yamada, Johann Zmeskal, Daniel S. Swetz
A performance evaluation of superconducting transition-edge sensors (TESs) in the environment of a pion beam line at a particle accelerator is presented. Averaged across the 209 functioning sensors in the array, the achieved energy resolution is 5.2 eV

Algorithms for Identification of Nearly-Coincident Events in Calorimetric Sensors

December 29, 2015
Author(s)
Bradley K. Alpert, Elena Ferri, Douglas A. Bennett, Marco Faverzani, Joseph W. Fowler, Andrea Giachero, James P. Hays-Wehle, Angelo Nucciotti, Daniel S. Swetz, Joel N. Ullom
For experiments with high arrival rates, reliable identification of nearly-coincident events can be crucial. For calorimetric measurements to directly measure the neutrino mass such as HOLMES, unidentified pulse pile-ups are expected to comprise a leading

Developments in time-division multiplexing of X-ray transition-edge sensors.

December 8, 2015
Author(s)
William B. Doriese, Kelsey M. Morgan, Douglas A. Bennett, Edward V. Denison, Colin P. Fitzgerald, Joseph W. Fowler, Johnathon D. Gard, James P. Hays-Wehle, Gene C. Hilton, Kent D. Irwin, Young Il Joe, John A. Mates, Galen C. O'Neil, Carl D. Reintsema, Nigel O. Robbins, Daniel R. Schmidt, Daniel S. Swetz, Hideyuki Tatsuno, Joel N. Ullom, Leila R. Vale
Time-division multiplexing (TDM) is a mature scheme for the readout of transition-edge sensors. Variants of TDM, which is based on superconducting-quantum-interference-device (SQUID) current amplifiers, have to date been field-deployed in several

Observation of Iron Spin-States using Tabletop X-ray Emission Spectroscopy and Microcalorimeter Sensors

December 2, 2015
Author(s)
Young Il Joe, Galen C. O'Neil, Luis Miaja Avila, Joseph W. Fowler, Kevin L. Silverman, Daniel S. Swetz, Joel N. Ullom, Ralph Jimenez
X-ray emission spectroscopy (XES) is a powerful probe of the electronic and chemical state of elemental species embedded within more complex compounds. X-ray sensors that combine high resolving power and high collecting efficiency are desirable for photon

The Practice of Pulse Processing

November 12, 2015
Author(s)
Joseph W. Fowler, Bradley K. Alpert, William B. Doriese, Young Il Joe, Galen C. O'Neil, Joel N. Ullom, Daniel S. Swetz
The analysis of data from x-ray microcalorimeters requires great care; their excellent intrinsic energy resolution cannot usually be achieved in practice without a statistically near-optimal pulse analysis and corrections for important systematic errors

Microcalorimeter Spectroscopy at High Pulse Rates: a Multi-Pulse Fitting Technique

August 24, 2015
Author(s)
Joseph W. Fowler, Bradley K. Alpert, William B. Doriese, Young Il Joe, Galen C. O'Neil, Cherno Jaye, Joel N. Ullom, Daniel A. Fischer, Daniel S. Swetz
Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each sensor must be

High-resolution X-ray emission spectroscopy with transition-edge sensors: present performance and future potential

May 1, 2015
Author(s)
W.Bertrand (Randy) Doriese, Joseph Fowler, Daniel Swetz, Cherno Jaye, Daniel A. Fischer, Carl D. Reintsema, Douglas Bennett, Leila R. Vale, Gene C. Hilton, Dan Schmidt, Joel Ullom, Jens Uhlig, Ujjwal Mandal, Galen O'Neil, Luis Miaja Avila, Young I. Joe, wilfrid fullagar, Fredrick P. Gustafsson, Dharma Kurunthu, Villy Sundstrom
X-ray emission spectroscopy (XES) is a powerful element-selective tool to analyze the oxidation states of atoms in complex compounds, determine their electronic configuration, and identify unknown compounds in challenging environments. Until now the low

Maximum-likelihood fits to histograms for improved parameter estimation

February 7, 2014
Author(s)
Joseph W. Fowler
Straightforward methods for adapting the familiar χ 2 statistic to histograms of discrete events and other Poisson distributed data generally yield biased estimates of the parameters of a model. The bias can be important even when the total number of

High resolution gamma-ray spectroscopy with a microwave-multiplexed TES array

November 11, 2013
Author(s)
Omid Noroozian, John A. Mates, Douglas A. Bennett, Justus A. Brevik, Joseph W. Fowler, Jiansong Gao, Robert D. Horansky, Kent D. Irwin, Daniel R. Schmidt, Joel N. Ullom, Zhao Kang
We demonstrate the first gamma-ray spectroscopy with a microwave-multiplexed two-pixel TES(transition-edge sensor) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum (FWHM) at 97 keV and an

Operation of gamma-ray microcalorimeters at elevated count rates using filters with constraints

May 15, 2013
Author(s)
Bradley K. Alpert, Robert D. Horansky, Douglas A. Bennett, William B. Doriese, Joseph W. Fowler, Andrew Hoover, Michael W. Rabin, Joel N. Ullom
We introduce a filter construction method for pulse processing that differs in two respects from that in standard optimal filtering, in which the average pulse shape and noise power spectral density are combined to create a convolution filter for

Table-top ultrafast x-ray microcalorimeter spectrometry for molecular structure

March 26, 2013
Author(s)
Jens (. Uhlig, William B. Doriese, Joseph W. Fowler, Daniel S. Swetz, Carl D. Reintsema, Douglas A. Bennett, Leila R. Vale, Gene C. Hilton, Kent D. Irwin, Joel N. Ullom, Ilari Maasilta, Wilfred Fullagar, Niklas Gador, Sophie Canton, Kimmo Kinnunen, Villy Sundstrom
This work presents an x-ray absorption measurement by use of ionizing radiation generated by a femtosecond pulsed laser source. The spectrometer was a microcalorimetric array whose pixels are capable of accurately measuring energies of individual radiation

A high resolution gamma-ray spectrometer based on superconducting microcalorimeters

September 28, 2012
Author(s)
Douglas A. Bennett, Robert D. Horansky, Daniel R. Schmidt, Andrew Hoover, Ryan Winkler, Bradley K. Alpert, James A. Beall, William B. Doriese, Joseph W. Fowler, Gene C. Hilton, Kent D. Irwin, Nathan J. Hoteling, Vincent Y. Kotsubo, John A. Mates, Galen C. O'Neil, Michael W. Rabin, Carl D. Reintsema, Francis J. Schima, Daniel S. Swetz, Leila R. Vale, Joel N. Ullom
Improvements in superconductor device fabrication, detector hybridization techniques, and superconducting quantum interference device readout have made square-centimeter-sized arrays of gammaray microcalorimeters, based on transition-edge sensors (TESs)

Demonstration of code-division multiplexing for x-ray microcalorimeters

February 13, 2012
Author(s)
Greg Stiehl, W.Bertrand (Randy) Doriese, Gene C. Hilton, Kent D. Irwin, Carl D. Reintsema, Dan Schmidt, Daniel Swetz, Joel Ullom, Leila R. Vale, Joseph Fowler
We demonstrate the code-division multiplexing (CDM) readout of eight transition-edge sensor microcalorimeters. The energy resolution is 3.0 eV (full width at half-maximum) or better at 5.9 keV, with a best resolution of 2.3 eV and a mean of 2.6 eV over the

Advanced Code-Division Multiplexers for Superconducting Detector Arrays

February 11, 2012
Author(s)
Kent D. Irwin, Hsiao-Mei Cho, William B. Doriese, Joseph W. Fowler, Gene C. Hilton, Michael D. Niemack, Carl D. Reintsema, Daniel R. Schmidt, Joel N. Ullom, Leila R. Vale
Multiplexers based on the modulation of superconducting quantum interference devices are now regularly used in multi-kilopixel arrays of superconducting detectors for astrophysics, cosmology, and materials analysis. Over the next decade, much larger arrays