Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Infiltration in energy modeling: a simple equation made better

Published

Author(s)

Lisa C. Ng, Andrew K. Persily, Steven J. Emmerich

Abstract

As building envelope performance and HVAC equipment efficiencies continue to be improved to reduce building energy use, a greater percentage of the total energy loss of a building can occur through envelope leakage. Although the energy impacts of unintended infiltration on a commercial building’s energy use can be significant, current energy simulations and building designs generally do not accurately account for envelope infiltration and the impacts of improved airtightness. New strategies to incorporate airflow calculations into building energy calculations have been developed, which are more accurate than current approaches in energy simulation software and easier to apply than multizone airflow modeling (Ng et al. 2014). These new strategies are based on relationships between infiltration rates calculated using multizone airflow models, weather conditions, and building characteristics, including envelope airtightness and HVAC system operation.
Citation
ASHRAE Journal
Volume
56
Issue
7

Citation

Ng, L. , Persily, A. and Emmerich, S. (2014), Infiltration in energy modeling: a simple equation made better, ASHRAE Journal, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=916076 (Accessed March 29, 2024)
Created August 8, 2014, Updated February 19, 2017