Dynamic and static magnetic anisotropy in thin-film cobalt zirconium tantalum

Published

Author(s)

John P. Nibarger, R Ewasko, Michael L. Schneider, Thomas J. Silva

Abstract

The magnetic anisotropy values of thin amorphous cobalt zirconium tantalum (CZT) films were determined from static and dynamic measurements. Dynamic techniques show a rotatable component of anisotropy that decreases with increasing longitudinal bias field from 200 to 0'48 A/m (2.5 to 0'0.6 Oe). The dynamic value of the anisotropy is important when using CZT in high-frequency magnetic applications. Static values were obtained with an induction-field magnetometer while dynamic values were obtained using a pulsed inductive microwave magnetometer.
Citation
Journal of Magnetism and Magnetic Materials
Volume
286

Keywords

anisotropy, CZT, magneto-dynamics, PIMM, rotatable anisotropy
Created October 26, 2004, Updated February 19, 2017