Studies of Intensity Noise at Synchrotron Ultraviolet Radiation Facility III

Published

Author(s)

Uwe Arp, Thomas B. Lucatorto, K Harkay, K Kim

Abstract

Suppression of beam instabilities has become an important goal at synchrotron radiation light sources, where highly sensitive applications like metrology, Fourier--transform spectroscopy and microscopy are now in use. We describe measurements connecting beam size and position changes to the onset of the saw-tooth instability and an instability generated by attempts to enlarge the vertical beam size for lifetime improvements.
Citation
Review of Scientific Instruments
Volume
73

Keywords

noise, noise detection, saw-tooth instability, synchrotran radiation

Citation

Arp, U. , Lucatorto, T. , Harkay, K. and Kim, K. (2002), Studies of Intensity Noise at Synchrotron Ultraviolet Radiation Facility III, Review of Scientific Instruments (Accessed April 18, 2024)