Note 1

To Conserve storage space the values stored in the Time_Series data item

have been converted to integer*2.

Integer*2 can store values ranging from -32767>+32767.

The pressure Coefficient data in this file has been multiplied a factor of 1000.

To convert the stored data back to pressure Coeficients the integer*2 values

must be multiplied by Ts_Multiplier (usually .001)   



Note 2

NIST profile Exposure One - open exposure - target zo = 0.03 m	

(9.8 Feet Fullscale)

					

column variables xyz=Full Scale Feet



1       2       3       4        5       6       7

x	y	z	V	Iu 	Iv 	Iw



Note 3

Wind direction: 0 deg defined as wind from (-1,0,0) to (0,0,0)

clockwise wind angles, center of turntable at (0.1905,0.1219) which 

corresponds to (62.5 , 40.0) feet in fullscale. 





Note 4

Model scale is 1:100



Note 5

Tap Statistics column names (item Tap_Max_Min_Mean_Rms) colums are

1	2	3	4	5

tap#   Max.    Min.    Mean    RMS