61. Measuring collected gas with microwave and acoustic resonances
Topic: High Performance Buildings
Published: 4/23/2015
Authors: Keith A Gillis, James W Schmidt, Michael R Moldover, James B. Mehl
Abstract: With calibrations of large flow meters in mind, we established the feasibility of determining the mass {I}M{/I} of argon gas contained within a 0.3 m^u3^ commercially manufactured pressure vessel ("tank") with a relative standard uncertainty of {I}u{ ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=918365

62. Metering of Fluids at High Velocities with Vortex Shedding Flowmeters
Series: Technical Note (NIST TN)
Report Number: 1501
Topic: High Performance Buildings
Published: 3/1/1998
Author: James D. Siegwarth
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=902010

63. Microwave Determination of the Volume of a Pressure Vessel
Topic: High Performance Buildings
Published: 12/9/2014
Authors: Michael R Moldover, James W Schmidt, Keith A Gillis, James B. Mehl, John D Wright
Abstract: Using microwave techniques that are scalable to very large volumes, we measured the interior volume of a 0.3 m^u3^, commercially-manufactured, pressure vessel with an uncertainty of 0.05 %, as confirmed by independent, more-accurate, gas-expansion me ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=917302

64. NIST Calibration Services for Gas Flow Meters: Piston Prover and Bell Prover Gas Flow Facilities
Series: Special Publication (NIST SP)
Report Number: 250-49
Topic: High Performance Buildings
Published: 8/1/1998
Authors: John D Wright, G E. Mattingly
Abstract: This document provides a description of the small and medium range gas flow calibration facilities at the National Institute of Standards and Technology (NIST), Fluid Flow Group, as reported in NIST Special Publication 250 for Test Nos. 18010C-18040C ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=830588

65. NIST Calibration Services for Water Flowmeters Water Flow Calibration Facility
Series: Special Publication (NIST SP)
Report Number: 250-73
Topic: High Performance Buildings
Published: 8/1/2006
Authors: Iosif I Shinder, Iryna V. Marfenko
Abstract: This document describes the Water Flow Calibration Facility (WFCF) at the National Institute of Standards and Technology (NIST). This facility has three parallel pipelines with diameters of 100, 200 and 400 mm and three weighing systems with capaciti ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=830979

66. NIST Micronutrients Measurement Quality Assurance Program Winter, Spring, and Fall 1994 Comparability Studies: Results for Round Robins XXX, XXXI, and XXXII Fat-Soluble Vitamins and Carotenoids in Human Serum and Round Robins 5 and 6 Ascorbic Acid in Human Serum
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 7880-30
Topic: High Performance Buildings
Published: 10/30/2014
Authors: Jeanice M Brown Thomas, Margaret C Kline, Katherine E Sharpless, S A. Margolis
Abstract: The National Institute of Standards and Technology coordinates the Micronutrients Measurement Quality Assurance Program (MMQAP) for laboratories that measure fat- and water-soluble vitamins and carotenoids in human serum and plasma. This report desc ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=916647

67. NIST Multizone Modeling Website
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 6728
Topic: High Performance Buildings
Published: 4/2/2001
Author: William S Dols
Abstract: This report presents an overview of the NIST Multizone Modeling Website developed by the Building and Fire Research Laboratory of the National Institute of Standards and Technology (NIST). Multizone modeling refers to the calculation of airflows, pr ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=860843

68. NIST Standard Reference Database 73 REFLEAK: NIST Leak/Recharge Simulation Model for Refrigerant Mixtures, Version 4.0
Topic: High Performance Buildings
Published: 1/16/2012
Authors: David Didion, MinSoo Kim, Piotr A Domanski
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=909788

69. Natural Gas Flow Calibration Service
Series: Special Publication (NIST SP)
Topic: High Performance Buildings
Published: 8/1/2008
Author: Aaron N Johnson
Abstract: This document describes NIST's high pressure natural gas flow calibration service (NGFCS). Flow calibrations are conducted offsite at the Colorado Experimental Engineering Station Incorporated (CEESI) in Garner, Iowa. A parallel array of nine tur ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=832323

70. Ontology Development For Low-Energy Building Embedded Commissioning
Topic: High Performance Buildings
Published: 11/17/2009
Authors: Kwang Jun Lee, Omer Akin, Burcu Akinci, James Garrett, Steven T Bushby
Abstract: This paper presents the results of initial work in developing an ontology for improving information exchange and automation in building system commissioning practices. In our previous research dealing with the derivation of product models from buildi ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=903791



Search NIST-wide:


(Search abstract and keywords)


Last Name:
First Name:







Special Publications:

Looking for a NIST Special Publication (NIST SP Series)? Place the series number and dash in the report number field (Example: 800-) and begin your search.

  • SP 250-XX: Calibration Services
  • SP 260-XX: Standard Reference Materials
  • SP 300-XX: Precision Measurement and Calibration
  • SP 400-XX: Semiconductor Measurement Technology
  • SP 480-XX: Law Enforcement Technology
  • SP 500-XX: Computer Systems Technology
  • SP 700-XX: Industrial Measurement Series
  • SP 800-XX: Computer Security Series
  • SP 823-XX: Integrated Services Digital Network Series