NIST logo

Publications Portal

You searched on:
Topic Area: Diagnostics
Sorted by: title

Displaying records 11 to 20 of 25 records.
Resort by: Date / Title


11. Determining carbapenemase activity with 18O labeling and targeted mass spectrometry
Topic: Diagnostics
Published: 10/16/2013
Authors: Meiyao Wang, Yang Shen, Illarion V Turko, Daniel Nelson, Shuwei Li
Abstract: Carbapenems are broad spectrum antibiotics considered as last resort drugs to treat bacterial infections. Carbapenem-hydrolyzing β-lactamases (also called carbapenemases), however, can confer bacterial resistance and represent a serious health t ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=914525

12. Epitope Selection of Monoclonal Antibodies for Interleukin-4 Quantification Using Suspension Arrays and Forward-Phase Protein Microarrays
Topic: Diagnostics
Published: 12/6/2007
Authors: Lili Wang, Kenneth D Cole, Hua-Jun He, Alexander W Peterson, Adolfas Kastytis Gaigalas, Y Zong
Abstract: A recombinant mouse interleukin-4 (IL-4) and three different purified rat anti-mouse IL-4 monoclonal antibodies (Mab) with different epitopes were employed as a model system. This system was used to examine monoclonal antibody effectiveness using bot ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=830554

13. GENERATING CELL CO-CULTURES BY RAPID CELL ADHESION ON OPPOSITE SIDES OF POLYESTER MEMBRANES
Topic: Diagnostics
Published: 10/28/2012
Authors: Conni Hanke, Petra S. Dittrich, Darwin R Reyes-Hernandez
Abstract: A cell co-culture was generated on opposite sides of a permeable polyester membrane (PET) membrane by combining dielectrophoretic (DEP) and electrostatic forces to hold cells against gravity in a multilayer microfluidic device (Figure 1). HepG2 cell ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=911771

14. MAGF: A New Method for High-performance Focusing of Uncharged and Hydrophobic Analytes
Topic: Diagnostics
Published: 10/1/2003
Authors: David J Ross, K M. Balss, P B. Howell, Wyatt N Vreeland
Abstract: A new method for analyte focusing is demonstrated that can be used for concentration and separation of analytes based upon their affinity for a micellar phase. The method works by producing (through the application of a temperature gradient) a gradie ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=830850

15. Microsensors in Dynamic Backgrounds: Toward Real-Time Breath Monitoring
Topic: Diagnostics
Published: 1/15/2010
Authors: Kurt D Benkstein, Baranidharan Raman, Christopher B Montgomery, C Martinez, Stephen Semancik
Abstract: We evaluated MEMS microsensor array with chemi-resistive elements for use as a non-invasive clinical diagnostic tool to detect the presence or absence of trace amounts of disease biomarkers in simulated breath samples. The microsensor environment was ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=901207

16. Mutual Recognition of Measurements: Its Potential Impact on International Trade in IVDs
Topic: Diagnostics
Published: 1/1/2002
Authors: Hratch G. Semerjian, Ellyn S. Beary
Abstract: International agreements and decisions concerning global trade, the environment and health care increasingly call for mutual recognition of measurements and standards between nations. Such mutual recognition can remove technical barriers to trade, fa ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=830012

17. Proceedings of the Workshop on Measurement Traceability for Clinical Laboratory Testing and In Vitro Diagnostic Test Systems
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 6742
Topic: Diagnostics
Published: 5/1/2001
Author: Ellyn S. Beary
Abstract: In November 2000, NIST hosted a workshop on Measurement Traceability for Clinical Laboratory Testing and In Vitro Diagnostic Devices. One of the driving forces was the new European Community (EC) In Vitro Diagnostic Devices (IVDD) directive that requ ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=830013

18. Quantitation of HER2 and Telomerase Biomarkers in Solid Tumors with IgY Antibodies and Nanocrystal Detection
Topic: Diagnostics
Published: 5/15/2008
Authors: Yan Xiao, X Gao, G Gannot, M Emmert-Buck, S Srivastava, Paul D Wagner, Michael D. Amos, Peter E. Dr. Barker
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=901234

19. Quantitative Analysis of Dendron-Conjugated Cisplatin-Complexed Gold Nanoparticles Using Scanning Particle Mobility Mass Spectrometry
Topic: Diagnostics
Published: 5/8/2013
Authors: De-Hao D. Tsai, Tae Joon Cho, Sherrie R. Elzey, Julien C. Gigault, Vincent A Hackley
Abstract: We report a high-resolution and traceable method to quantify the drug loading on nanoparticle-based cancer therapeutics, and demonstrate this method using a model cisplatin functionalized dendron-gold nanoparticle (AuNP) conjugate. Electrospray diffe ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=912782

20. Quantum Dot FRET Sensor for Enzymatic Activity in Microfluidic Device
Topic: Diagnostics
Published: 6/22/2010
Authors: Georgeta Crivat, Sandra Maria Da Silva, Darwin R Reyes-Hernandez, Samuel P Forry, Laurie E Locascio, Michael Gaitan, Nitsa Rosenzweig, Zeev Rosenzweig
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=907085



Search NIST-wide:


(Search abstract and keywords)


Last Name:
First Name:







Special Publications:

Looking for a NIST Special Publication (NIST SP Series)? Place the series number and dash in the report number field (Example: 800-) and begin your search.

  • SP 250-XX: Calibration Services
  • SP 260-XX: Standard Reference Materials
  • SP 300-XX: Precision Measurement and Calibration
  • SP 400-XX: Semiconductor Measurement Technology
  • SP 480-XX: Law Enforcement Technology
  • SP 500-XX: Computer Systems Technology
  • SP 700-XX: Industrial Measurement Series
  • SP 800-XX: Computer Security Series
  • SP 823-XX: Integrated Services Digital Network Series