NIST logo

Publications Portal

You searched on:
Topic Area: Bioscience
Health

Displaying records 81 to 90 of 462 records.
Resort by: Date / Title


81. Giant piezoelectricity in PMN-PT thin films: Beyond PZT
Topic: Bioscience & Health
Published: 11/1/2012
Authors: S. H. Baek, M. S. Rzchowski, Vladimir A Aksyuk
Abstract: Micro-electromechanical systems (MEMS) incorporating piezoelectric layers provide active transduction between electrical and mechanical energy, which enables highly sensitive sensors and low-voltage driven actuators surpassing the passive operation o ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=912113

82. Manipulating the Color and Shape of Single Photons
Topic: Bioscience & Health
Published: 11/1/2012
Authors: Michael G. Raymer, Kartik A Srinivasan
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=912051

83. Time-Resolved Terahertz Studies of Carrier Dynamics in P3HT and Zinc-Phthalocyanine/C60 Nanolayered Organic Films
Topic: Bioscience & Health
Published: 10/19/2012
Authors: Edwin J Heilweil, Paul A. Lane, Okan Esenturk, Paul D. Cunningham, Joseph S Melinger
Abstract: Relative carrier mobilities in semiconducting organic polymer films measured using non-contact optical pump terahertz (THz) probe spectroscopy will be presented. Transient signal amplitude measurements of photo-injected mobility as a function of pol ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=912644

84. Two-photon interference using background-free quantum frequency conversion of single photons emitted by an InAs quantum dot
Topic: Bioscience & Health
Published: 10/4/2012
Authors: Serkan Ates, Imad I. Agha, Angelo Gulinatti, Ivan Rech, Matthew T. Rakher, Antonio Badolato, Kartik A Srinivasan
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=911349

85. Electro-Thermal Simulation and Design of a 60 A, 4.5 kV Half-Bridge Si IGBT/SiC JBS Hybrid Power Module
Topic: Bioscience & Health
Published: 9/15/2012
Authors: Tam Hoang Duong, Allen R Hefner Jr, Karl Hobart
Abstract: This paper presents the results from a parametric simulation study that was conducted to optimize the design of a high-current 4.5 kV half-bridge Si-IGBT/SiC-JBS hybrid module for medium voltage hard-switched power conversion as well as to compare th ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=911712

86. Evaluation of viability and proliferation profiles on macrophages treated with silica nanoparticles in vitro via plate-based, flow cytometry, and Coulter counter assays
Topic: Bioscience & Health
Published: 9/3/2012
Authors: Simona Bancos, De-Hao D. Tsai, Vincent A Hackley, J L Weaver, Katherine M Tyner
Abstract: Nanoparticles (NPs) are known to interfere with many high throughput cell viability and cell proliferation assays, which complicates the assessment of their potential toxic effects. The aim of this study was to compare viability and proliferation res ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=911765

87. Disentangling the effects of polymer coatings on silver nanoparticle agglomeration, dissolution, and toxicity to determine mechanisms of nanotoxicity
Topic: Bioscience & Health
Published: 9/1/2012
Authors: Justin M Zook, Melissa Danielle Halter, Danielle Cleveland, Stephen E Long
Abstract: Silver nanoparticles (AgNPs) are frequently coated by a variety of polymers, which may affect various intertwined mechanisms of toxicity, including agglomeration and dissolution rate. Here, we measure how citrate, dextran, poly(ethylene glycol) (PEG ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=908497

88. Probing coherence in microcavity frequency combs via optical pulse shaping
Topic: Bioscience & Health
Published: 8/29/2012
Authors: Fahmida Ferdous, Houxun H. Miao, Pei-Hsun Wang, Daniel E. Leaird, Kartik A Srinivasan, Lei Chen, Vladimir A Aksyuk, Andrew M Weiner
Abstract: Recent investigations of microcavity frequency combs based on cascaded four-wave mixing have revealed a link between the evolution of the optical spectrum and the observed temporal coherence. Here we study a silicon nitride microresonator for which ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=911692

89. Review: Biological Imaging Software Tools
Topic: Bioscience & Health
Published: 8/29/2012
Authors: Anne L Plant, Kevin Eliceiri, Anne Carpenter
Abstract: Few technologies are more widespread in modern biological laboratories than imaging by microscopy. Advancements in optical technologies and instrumentation over the past twenty years have led to massive improvements in the resolution, specificity, d ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=911485

90. Synthetic spike-in standards improve run-specific systematic error analysis for DNA and RNA sequencing
Topic: Bioscience & Health
Published: 7/31/2012
Authors: Justin M Zook, Daniel Victor Samarov, Jennifer H McDaniel, Shurjo Sen, Marc L Salit
Abstract: While the importance of random sequencing errors decreases at higher DNA or RNA sequencing depths, systematic sequencing errors (SSEs) dominate at high sequencing depths and can be difficult to distinguish from biological variants. These SSEs can ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=910640



Search NIST-wide:


(Search abstract and keywords)


Last Name:
First Name:







Special Publications:

Looking for a NIST Special Publication (NIST SP Series)? Place the series number and dash in the report number field (Example: 800-) and begin your search.

  • SP 250-XX: Calibration Services
  • SP 260-XX: Standard Reference Materials
  • SP 300-XX: Precision Measurement and Calibration
  • SP 400-XX: Semiconductor Measurement Technology
  • SP 480-XX: Law Enforcement Technology
  • SP 500-XX: Computer Systems Technology
  • SP 700-XX: Industrial Measurement Series
  • SP 800-XX: Computer Security Series
  • SP 823-XX: Integrated Services Digital Network Series