NIST logo

Publications Portal

You searched on:
Topic Area: Bioscience
Health

Displaying records 451 to 459.
Resort by: Date / Title


451. Assuring Confidence in Measurements in Biomedical Research
Topic: Bioscience & Health
Published: Date unknown
Authors: Anne L Plant, Laurie E Locascio, Willie E May, Patrick D Gallagher
Abstract: ,Irreproducibility‰ is a symptom of a broad challenge in measurement that needs to be addressed. Establishing a robust measurement process that will lead to greater confidence in biomedical research results will require a concerted effort from exper ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=916025

452. Characterization of Standard Reference Material 2942, Ce-Ion-Doped Glass, Spectral Correction Standard for UV Fluorescence
Topic: Bioscience & Health
Published: Date unknown
Authors: Paul C DeRose, Melody V Smith, Klaus Mielenz, Jeffrey R. Anderson, Gary W Kramer
Abstract: Standard Reference Material (SRM) 2942 is a cuvette-shaped, Ce-ion-doped glass, recommended for use for relative spectral correction of emission and day-to-day performance verification of steady-state fluorescence spectrometers. Properties of this st ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=906188

453. Chorismate Lyase at 0.9 Resolution
Topic: Bioscience & Health
Published: Date unknown
Authors: David Travis Gallagher, A Howard
Abstract: Chorismate
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=830442

454. Development of Multicolor Flow Cytometry Standards: Assignment of Equivalent Reference Fluorophores (ERF) Unit
Series: Journal of Research (NIST JRES)
Topic: Bioscience & Health
Published: Date unknown
Authors: Lili Wang, Adolfas Kastytis Gaigalas
Abstract: A procedure is described for assigning values of the number of equivalent reference fluorophores (ERF) to microspheres labeled with a fluorophore designed to produce fluorescence in a given channel of a multicolor flow cytometer. There is a different ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=906632

455. Extracting Two Parameters From a P2 Orientation Distribution
Topic: Bioscience & Health
Published: Date unknown
Authors: Curtis W Meuse, Joseph Bunton Hubbard
Abstract: Individual molecules are seldom identical. This poses a problem for optical spectroscopy. For instance, if molecular property distributions are not characterized, differences in the distribution of molecular properties between sample and standards ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=830583

456. Structural Calcium (Trypsin, Subtilisin)
Topic: Bioscience & Health
Published: Date unknown
Authors: G L. Gilliland, A Teplyakov
Abstract: There are about 40 families of serine proteases defined by amino acid sequence similarities that can be further grouped into 7 clans on the basis of their tertiary structure and the order of the catalytic triad.^u1^ Members of clans SA and SB are c ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=830437

457. Direct Measurement of Intrinsic Dirac Point and Fermi level at Graphene/Oxide interface and Its Band Alignment by Cavity Enhanced Internal Photoemission
Topic: Bioscience & Health
Published: 12/17/0012
Authors: Kun Xu, Caifu Zeng, Qin Q. Zhang, Rusen Yan, Peide Ye, Kang Wang, Alan C. Seabaugh, Huili G. Xing, John S Suehle, Curt A Richter, David J Gundlach, Nhan V Nguyen
Abstract: We report the first direct measurement of the Dirac point, the Fermi level, and the work function of graphene by performing internal photoemission measurements on a graphene/SiO2/Si structure with a unique optical-cavity enhanced test structure. ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=912242

458. High Temperature Electrical Resistance of substrate-supported Single Walled Carbon Nanotubes
Topic: Bioscience & Health
Published: 1/1/0008
Authors: Richard E Cavicchi, C Avedisian, Paul M. McEuen, Xinjian Zhou, Wilbur S. Hurst, Joseph Terence Hodges
Abstract: We report the electrical characteristics of two substrate-supported metallic single walled carbon nanotubes (SWNT) at temperatures up to 573 K over a range of bias voltages for zero gate voltage in air under atmospheric pressure. At low voltages or ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=832383

459. High-Resolution Cavity Ring-Down Spectroscopy of H216O at 10687.36 cm-1
Topic: Bioscience & Health
Published: 2/11/0004
Author: Joseph Terence Hodges
Abstract: We describe a frequency-stabilized cavity ring-down spectroscopy apparatus enabling high-resolution line shape measurements of water vapor. The measured line strength and broadening parameter for the H216O transition at 10687.36 cm-1 are compared to ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=830856



Search NIST-wide:


(Search abstract and keywords)


Last Name:
First Name:







Special Publications:

Looking for a NIST Special Publication (NIST SP Series)? Place the series number and dash in the report number field (Example: 800-) and begin your search.

  • SP 250-XX: Calibration Services
  • SP 260-XX: Standard Reference Materials
  • SP 300-XX: Precision Measurement and Calibration
  • SP 400-XX: Semiconductor Measurement Technology
  • SP 480-XX: Law Enforcement Technology
  • SP 500-XX: Computer Systems Technology
  • SP 700-XX: Industrial Measurement Series
  • SP 800-XX: Computer Security Series
  • SP 823-XX: Integrated Services Digital Network Series