101. High-Precision Pressure Shifting Measurement Technique Using Frequency-Stabilized Cavity Ring-Down Spectroscopy
Topic: Spectroscopy
Published: 1/1/0008
Authors: D J Robichaud, Joseph Terence Hodges, D Lisak, Charles E Miller, Mitchio Okumura
Abstract: We describe a high-precision method for measuring pressure shifting of absorption lines. The technique involves the acquisition of high-resolution spectra using a cavity ring-down spectrometer whose length is continuously locked to a frequency-stabil ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=831000

102. High- Resolution Cavity Ring-Down Spectroscopy Measurements of Blended H^d2^0 Transitions
Topic: Spectroscopy
Published: 1/1/0007
Authors: D Lisak, Joseph Terence Hodges
Abstract: We probed four closely spaced rovibrational water vapor absorption transitions near wavenumber = 7100 cm(^-1) using frequency-stabilized cavity ring-down spectroscopy. Room-temperature spectra were acquired for pure water vapor in the Doppler limit a ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=830992

103. High-Resolution Cavity Ring-Down Spectroscopy of H216O at 10687.36 cm-1
Topic: Spectroscopy
Published: 2/11/0004
Author: Joseph Terence Hodges
Abstract: We describe a frequency-stabilized cavity ring-down spectroscopy apparatus enabling high-resolution line shape measurements of water vapor. The measured line strength and broadening parameter for the H216O transition at 10687.36 cm-1 are compared to ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=830856

104. On the Application of Quantitative Cavity Ring Down Spectroscopy to Measruements of Line Shapes and Continuum Absorption
Topic: Spectroscopy
Published: 6/7/0002
Authors: J G. Cormier, Joseph Terence Hodges, J R Drummond
Abstract: Cavity ringdown spectroscopy (CRDS) is a highly sensitive spectroscopic technique that has been successfully applied to problems such as trace gas detection and the observation of weak spectra. Despite possessing several intrinsic advantages over oth ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=830795



Search NIST-wide:


(Search abstract and keywords)


Last Name:
First Name:







Special Publications:

Looking for a NIST Special Publication (NIST SP Series)? Place the series number and dash in the report number field (Example: 800-) and begin your search.

  • SP 250-XX: Calibration Services
  • SP 260-XX: Standard Reference Materials
  • SP 300-XX: Precision Measurement and Calibration
  • SP 400-XX: Semiconductor Measurement Technology
  • SP 480-XX: Law Enforcement Technology
  • SP 500-XX: Computer Systems Technology
  • SP 700-XX: Industrial Measurement Series
  • SP 800-XX: Computer Security Series
  • SP 823-XX: Integrated Services Digital Network Series