NIST logo

Publications Portal

You searched on: Author: howard yoon Sorted by: date

Displaying records 21 to 30 of 127 records.
Resort by: Date / Title

21. SP250 Spectral Irradiance Calibrations
Series: Special Publication (NIST SP)
Report Number: 250-89
Published: 7/25/2011
Authors: Howard W Yoon, Charles E Gibson
Abstract: This document describes the process of the realization, the maintenance and the dissemination of the spectral irradiance scale and its accompanying uncertainties at the National Institute of Standards and Technology. It describes the measurement pro ...

22. EMPS: Radiation Thermometer Designs
Published: 7/1/2010
Authors: Howard W Yoon, George P Eppeldauer
Abstract: Since the publication of the ,Theory and Practice of Radiation ThermometryŠ in 1988, the designs of radiation thermometers have undergone drastic changes. With the exception of few industries, the disappearing filament pyrometers are not commonly us ...

23. Long-Term Monitoring of the Ultraviolet Irradiance Scale at the Facility for Irradiance Calibration Using Synchrotrons
Published: 6/18/2010
Authors: Zhigang Li, Ping-Shine Shaw, Uwe Arp, Charles E Gibson, Howard W Yoon, Keith R Lykke
Abstract: In 2004, the National Institute of Standards and Technology (NIST) established the ultraviolet (UV) spectral irradiance scale from 200 nm to 400 nm using the calculable irradiance of the Synchrotron Ultraviolet Radiation Facility (SURF). Since the es ...

24. Calibrations of Current-to-Voltage Transimpedance Amplifiers Using Electrical Standards
Published: 6/13/2010
Authors: Howard W Yoon, George P Eppeldauer, Dean G Jarrett, Thomas C Larason, Wan-Seop Kim
Abstract: For photocurrent measurements with low uncertainties, a wide-dynamic range current-to-voltage converter traceable to resistance standards has been developed at the NIST. The design and calibration of the converter standard are described. For validat ...

25. Spectral irradiance responsivity calibration of InSb radiometers using the improved IR-SIRCUS at NIST
Published: 10/15/2009
Authors: Jinan Zeng, Howard W Yoon, George P Eppeldauer, Leonard M Hanssen, Joseph Paul Rice
Abstract: The spectral irradiance responsivity calibrations of InSb radiometers measured on the tunable-laser based Infrared Spectral Irradiance and Radiance Responsivity Calibration with Uniform Sources (IR-SIRCUS) facility are discussed. This work describes ...

26. The Extension of the NIST BRDF Scale from 1100 nm to 2500 nm
Published: 8/21/2009
Authors: Howard W Yoon, David W Allen, George P Eppeldauer, Benjamin K Tsai
Abstract: Measurements of bi-directional reflectance factor for diffuse reflectance from 1100 nm to 2500 nm using extended-range indium gallium arsenide (exInGaAs) detectors in the NIST Spectral Tri-function Automated Reference Reflectometer (STARR) facility ...

27. Spectroradiometric Characterization of the NIST Pulsed Solar Simulator
Published: 8/20/2009
Authors: Howard W Yoon, Brian P Dougherty, Vladimir Khromchenko
Abstract: The spectroradiometric characterization of the NIST indoor pulsed solar simulator is described. The solar simulator has a flash duration of 36.4 ms and is designed for solar panels having a maximum size of 2.0 m by 1.6 m. As per industry standards, ...

28. CCPR-S1 Supplementary Comparison for Spectral Radiance in the range of 220 nm to 2500 nm
Published: 6/2/2009
Authors: Boris Khlevnoy, Victor Sapritsky, Bernard Rougie, Charles E Gibson, Howard W Yoon, Arnold A. Gaertner, Dieter Taubert, Juergen Hartmann
Abstract: In 1997, the Consultative Committee for Photometry and Radiometry (CCPR) initiated a supplementary comparison of spectral radiance in the wavelength range from 220 nm to 2500 nm (CCPR S1) using tungsten -strip filament lamps as transfer standards. Fi ...

29. Extension of the NIST spectral responsivity scale to the infrared using improved-NEP pyroelectric detectors
Published: 6/2/2009
Authors: George P Eppeldauer, Jinan Zeng, Howard W Yoon, Boris Wilthan, Thomas C Larason, Leonard M Hanssen
Abstract: Routine NIST spectral responsivity calibrations are needed for the infrared range. Low NEP pyroelectric radiometers have been developed for traditional monochromator applications to extend the responsivity scale to the infrared. After NEP tests, the ...

30. Radiometer standard for absolute responsivity calibrations from 950 nm to 1650 nm with 0.05% (k = 2) uncertainty
Published: 6/2/2009
Authors: George P Eppeldauer, Howard W Yoon, Yuqin Zong, Thomas C Larason, Allan W. Smith, M. Racz
Abstract: A sphere-input transfer-standard detector has been developed to calibrate detectors and radiometers for absolute spectral power, irradiance, and radiance responsivity in the near-IR range with uncertainties similar to those of silicon trap-detector c ...

Search NIST-wide:

(Search abstract and keywords)

Last Name:
First Name:

Special Publications:

Looking for a NIST Special Publication (NIST SP Series)? Place the series number and dash in the report number field (Example: 800-) and begin your search.

  • SP 250-XX: Calibration Services
  • SP 260-XX: Standard Reference Materials
  • SP 300-XX: Precision Measurement and Calibration
  • SP 400-XX: Semiconductor Measurement Technology
  • SP 480-XX: Law Enforcement Technology
  • SP 500-XX: Computer Systems Technology
  • SP 700-XX: Industrial Measurement Series
  • SP 800-XX: Computer Security Series
  • SP 823-XX: Integrated Services Digital Network Series