NIST logo

Publications Portal

You searched on: Author: enrico lucon Sorted by: title

Displaying records 1 to 10 of 24 records.
Resort by: Date / Title


1. Certification Report for SRM 2216, 2218, 2219: KLST (Miniaturized) Charpy V-Notch Impact Specimens
Series: Special Publication (NIST SP)
Report Number: 260-180
Published: 7/23/2013
Author: Enrico Lucon
Abstract: This Certification Report documents the procedures used to develop certified values of maximum force (Fm) and absorbed energy (KV) for the following KLST-type miniaturized verification Charpy V-notch impact specimens: , SRM 2216 (low-energy leve ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=914116

2. Certified KLST Miniaturized Charpy Specimens for the Indirect Verification of Small-Scale Impact Machines
Published: 4/28/2015
Authors: Enrico Lucon, Christopher N McCowan, Raymond L Santoyo, Jolene D Splett
Abstract: Small specimen test techniques are becoming ever more popular as the need increases to characterize mechanical properties by use of the smallest possible amount of material, due to various restrictions on material availability, irradiation, testing s ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=915292

3. Certified Miniaturized Charpy Specimens for the Indirect Verification of Small-Size Impact Machines
Published: 6/27/2013
Author: Enrico Lucon
Abstract: Small specimen test techniques are becoming ever more popular as the need increases to characterize mechanical properties by use of the smallest possible amount of material, due to various restrictions on material availability, irradiation, testing s ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=912119

4. Determination of the compliance of NIST Charpy Impact Machines
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 8043
Published: 2/10/2015
Author: Enrico Lucon
Abstract: The compliance of a Charpy impact machine, CM, can be measured by means of a low-blow elastic test on an unnotched Charpy-type specimen, provided an instrumented striker is used. The resulting force/time and force/displacement test records can be ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=917638

5. Effect of Electrical Discharge Machining (EDM) on Charpy Test Results from Miniaturized Steel Specimens
Series: Technical Note (NIST TN)
Published: 12/11/2012
Author: Enrico Lucon
Abstract: Electrical Discharge Machining (EDM) is a manufacturing process whereby a desired shape is obtained through electrical discharges between an electrode and a workpiece, separated by a dielectric fluid. EDM produces a damage layer on the surface of the ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=910127

6. Effect of Electrical Discharge Machining (EDM) on Miniaturized Charpy Test Results
Published: 12/11/2012
Author: Enrico Lucon
Abstract: Electrical Discharge Machining (EDM) is a manufacturing process whereby a desired shape is obtained through electrical discharges between an electrode and a workpiece, separated by a dielectric fluid. EDM produces a recast layer on the surface of the ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=910266

7. Elastic-Plastic Fracture Toughness Tests on X100 Pipeline Steel Using Specimens of Different Configurations
Published: 8/1/2011
Authors: Enrico Lucon, Timothy S Weeks, D. Y. Park, James Gianetto, G Shen, R S Eagleson
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=909626

8. Establishment of an International Scale for Instrumented Charpy Testing: comparison between NIST and LNE
Series: Technical Note (NIST TN)
Report Number: 1875
Published: 4/1/2015
Authors: Enrico Lucon, Christopher N McCowan, Raymond L Santoyo, Stephane Lefrancois
Abstract: As a contribution to the establishment of an international scale for instrumented Charpy testing, aimed at ensuring that impact forces are obtained more accurately, NIST and Laboratoire National de métrologie et d‰Essais (LNE, France) have partic ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=917575

9. Evaluation of Bias for Two Charpy Impact Machines Using the Same Instrumented Striker
Published: 5/1/2011
Authors: Christopher N McCowan, Enrico Lucon, Raymond L Santoyo
Abstract: Two Charpy machines were used to test NIST verification specimens at three energy levels: low energy (≈ 15 J at -40°C), high energy (≈ 100 J at -40°C) and super-high energy (≈ 240 J at room temperature). The study evaluates the diff ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=905891

10. Fracture Toughness Characterization of High-Pressure Pipe Girth Welds Using Single-Edge Notched Tension SE(T) Specimens
Published: 8/28/2014
Authors: Enrico Lucon, Timothy S Weeks, James Gianetto, W. R. Tyson, D. Y. Park
Abstract: The safety and reliability of large-diameter pipelines for the transport of fluid hydrocarbons is being improved by the development of high-strength steels, advanced weld technologies and strain-based design (SBD) methodologies. Strain-based design i ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=915206



Search NIST-wide:


(Search abstract and keywords)


Last Name:
First Name:







Special Publications:

Looking for a NIST Special Publication (NIST SP Series)? Place the series number and dash in the report number field (Example: 800-) and begin your search.

  • SP 250-XX: Calibration Services
  • SP 260-XX: Standard Reference Materials
  • SP 300-XX: Precision Measurement and Calibration
  • SP 400-XX: Semiconductor Measurement Technology
  • SP 480-XX: Law Enforcement Technology
  • SP 500-XX: Computer Systems Technology
  • SP 700-XX: Industrial Measurement Series
  • SP 800-XX: Computer Security Series
  • SP 823-XX: Integrated Services Digital Network Series