NIST logo

Publications Portal

You searched on:
Author: mark kedzierski

Displaying records 41 to 50 of 90 records.
Resort by: Date / Title


41. Effect of Refrigerant Oil Additive on R134a and R123 Boiling Heat Transfer Performance
Report Number: 7132
Published: 1/1/2007
Author: Mark A Kedzierski
Abstract: This paper investigates the effect that an additive had on the boiling performance of an R134a/polyolester lubricant (POE) mixture and an R123/naphthenic mineral oil mixture on a roughened, horizontal flat surface. Both pool boiling heat transfer da ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=860950

42. Contamination and Decontamination of Building Plumbing Systems
Published: 9/25/2006
Authors: Stephen J. Treado, Mark A Kedzierski, Stephanie S Watson, Kenneth D Cole
Abstract: The quality of drinking water has always been a subject of interest. In fact, a stable and secure supply of clean drinking water is a hallmark of modern society. Recently, new concerns have arisen regarding the potential occurrence of intentional o ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=861032

43. Development of a Fluorescence Based Measurement Technique to Quantify Water Contaminants at Pipe Surfaces During Flow
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 7355
Published: 9/1/2006
Author: Mark A Kedzierski
Abstract: This paper provides a detailed account of the development of a fluorescence based measurement technique for measuring the mass of contaminant on solid surfaces in the presence of water flow. A test apparatus was design and developed for the purpose ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=861020

44. Influence of Concentration and Additives on R123/Paraffinic Material Oil Boiling Heat Transfer Performance (NISTIR 7336)
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 7336
Published: 9/1/2006
Authors: Mark A Kedzierski, D H Han
Abstract: This paper investigates the effect that oil concentration had on the boiling performance of an R123/paraffinic mineral oil mixture on a roughened, horizontal flat surface. For all compositions, the lubricant caused a heat transfer degradation relati ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=861025

45. Report of Phase One Measurement and Analysis of Building Water System Contamination and Decontamination
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 7351
Published: 7/3/2006
Authors: Stephen J. Treado, Mark A Kedzierski, Stephanie S Watson, Dale P Bentz, Nicos Martys, Kenneth D Cole
Abstract: This report describes the results of the first phase of a research project to evaluate how contaminants accidentally or intentionally introduced into the water supply might accumulate in building plumbing systems, and how these contaminants might be ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=861008

46. A Comparison of R245fa Pool Boiling Measurements to R123, and R245fa/Isopentane on a Passively Enhanced, Horizontal Surface
Published: 4/3/2006
Author: Mark A Kedzierski
Abstract: This study presents pool boiling heat transfer measurements for R245fa, R123 and a mixture of R245fa and isopentane on a flattened passively enhanced low-pressure boiling surface. Possibly because the enhanced surface was flattened from a round tube, ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=860961

47. Horizontal Convective Boiling of Refrigerants and Refrigerant Mixtures Within a Micro-Fin Tube
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 7243
Published: 7/1/2005
Authors: L J Hamilton, Mark A Kedzierski, M P Kaul
Abstract: This paper presents local convective boiling measurements in a micro-fin tube for four pure refrigerants: R22, R32, R125, and R134a; and four refrigerant mixtures: R410B (R32/125, 45/55 % mass), R32/R134a (28/72 % and 30/70% mass) and, R407C (R32/12 ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=860975

48. Effect of Bulk Lubricant Concentration on the Excess Surface Density During R134a Pool Boiling with Extensive Measurement and Analysis Details
Series: NIST Interagency/Internal Report (NISTIR)
Published: 6/1/2005
Author: Mark A Kedzierski
Abstract: This paper investigates the effect that the bulk lubricant concentration has on the non-adiabatic lubricant excess surface density on a roughened, horizontal flat pool-boiling surface. Both pool boiling heat transfer data and lubricant excess surfac ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=860932

49. Effect of Bulk Lubricant Concentration on the Excess Surface Density During R134a Pool Boiling
Published: 1/21/2005
Author: Mark A Kedzierski
Abstract: This paper investigates the effect that the bulk lubricant concentration has on the non-adiabatic lubricant excess surface density on a roughened, horizontal flat pool-boiling surface. Both pool boiling heat transfer data and lubricant excess surface ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=910408

50. Effect of Refrigerant Oil Additive on R134a and R123 Boiling Heat Transfer Performance and Related Issues for GSA.
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 7132
Published: 12/1/2004
Author: Mark A Kedzierski
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=101412



Search NIST-wide:


(Search abstract and keywords)


Last Name:
First Name:







Special Publications:

Looking for a NIST Special Publication (NIST SP Series)? Place the series number and dash in the report number field (Example: 800-) and begin your search.

  • SP 250-XX: Calibration Services
  • SP 260-XX: Standard Reference Materials
  • SP 300-XX: Precision Measurement and Calibration
  • SP 400-XX: Semiconductor Measurement Technology
  • SP 480-XX: Law Enforcement Technology
  • SP 500-XX: Computer Systems Technology
  • SP 700-XX: Industrial Measurement Series
  • SP 800-XX: Computer Security Series
  • SP 823-XX: Integrated Services Digital Network Series