21. CONTAMW/X 2.1 Supplemental User Guide and Program Documentation
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 7049
Published: 10/23/2003
Authors: George Walton, William S Dols
Abstract: CONTAMW is a general purpose, multi-zone (nodal) airflow and contaminant transport analysis tool that can be used to determine interzone pressure differences, airflow rates and contaminant transport in complex building structures. This tool was deve ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=860931

22. Impact of Natural Ventilation Strategies and Design Issues for California Applications, Including Input to ASHRAE Standard 62 and California Title 24-Report on Task 4.4.3a and 4.4.3b of CEC-EEB RMT Project
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 7062
Published: 10/1/2003
Authors: Steven J Emmerich, Andrew Keith Persily, William S Dols, James W Axley
Abstract: Natural ventilation has the potential to reduce the energy required for cooling and ventilating commercial buildings while still providing acceptable thermal comfort and indoor air quality. While a recent surge of interest in Europe has advanced natu ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=860930

23. LoopDA -- A Natural Ventilation System Design and Analysis Tool
Published: 8/1/2003
Authors: William S Dols, Steven J Emmerich
Abstract: The Loop Equation Design Method has been proposed for sizing ventilation airflow components of natural and hybrid ventilation systems. While the loop design method has been demonstrated on a limited basis, the method has been automated in order to be ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=860913

24. Development of IAQ Model Input Databases: Volatile Organic Compound Source Emission Rates.
Published: 7/23/2003
Authors: Cynthia H. Reed, Brian J Polidoro, William S Dols
Abstract: Indoor air quality (IAQ) models are often used to predict airflows, contaminant concentrations and personal exposures for a given indoor environment. In order to generate such results, these models typically require the user to provide a wide range o ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=860917

25. LoopDA-Natural Ventilation Design and Analysis Software
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 6967
Published: 4/1/2003
Authors: William S Dols, Steven J Emmerich
Abstract: The Loop Equation Design Method has been proposed for sizing ventilation airflow components of natural and hybrid ventilation systems. While the approach has been demonstrated on a limited basis, the method has been automated in order to better eval ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=860904

26. CONTAMW 2.0 User Manual
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 6921
Published: 11/1/2002
Authors: William S Dols, George Walton
Abstract: This manual describes the computer program CONTAMW version 2.0 developed by NIST. CONTAMW is a multizone indoor air quality and ventilation analysis program designed to help you determine: airflows and pressures infiltration, exfiltration, and roo ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=860889

27. A Method to Assess the Suitability of a Climate for Natural Ventilation of Commercial Buildings
Published: 7/1/2002
Authors: Steven J Emmerich, William S Dols, James W Axley
Abstract: Natural ventilation has the potential to reduce first costs and operating costs for some commercial buildings while maintaining ventilation rates consistent with acceptable indoor air quality. While a recent surge of interest in Europe has advanced ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=861064

28. An Approach to the Design of Natural and Hybrid Ventilation Systems for Cooling Buildings
Published: 7/1/2002
Authors: James W Axley, Steven J Emmerich, William S Dols, George Walton
Abstract: This paper presents an approach to the design of natural and hybrid ventilation systems that accounts for specific climatic and operational conditions and is organized to serve the building designer at each distinct phase of design predesign analys ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=860870

29. Natural Ventilation Review and Plan for Design and Analysis Tools
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 6781
Published: 8/1/2001
Authors: Steven J Emmerich, William S Dols, James W Axley
Abstract: Natural ventilation has the potential to reduce first costs and operating costs for some commercial buildings while maintaining ventilation rates consistent with acceptable indoor air quality. While a recent surge of interest in Europe has advanced ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=860854

30. NIST Multizone Modeling Website
Series: NIST Interagency/Internal Report (NISTIR)
Report Number: 6728
Published: 4/2/2001
Author: William S Dols
Abstract: This report presents an overview of the NIST Multizone Modeling Website developed by the Building and Fire Research Laboratory of the National Institute of Standards and Technology (NIST). Multizone modeling refers to the calculation of airflows, pr ...
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=860843



Search NIST-wide:


(Search abstract and keywords)


Last Name:
First Name:







Special Publications:

Looking for a NIST Special Publication (NIST SP Series)? Place the series number and dash in the report number field (Example: 800-) and begin your search.

  • SP 250-XX: Calibration Services
  • SP 260-XX: Standard Reference Materials
  • SP 300-XX: Precision Measurement and Calibration
  • SP 400-XX: Semiconductor Measurement Technology
  • SP 480-XX: Law Enforcement Technology
  • SP 500-XX: Computer Systems Technology
  • SP 700-XX: Industrial Measurement Series
  • SP 800-XX: Computer Security Series
  • SP 823-XX: Integrated Services Digital Network Series