Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Movement on Stairs During Building Evacuations

Published

Author(s)

Erica D. Kuligowski, Richard Peacock, Paul A. Reneke, Emily A. Wiess, Jason D. Averill, Robert Hagwood, Enrico Ronchi, Bryan Hoskins, Michael Spearpoint

Abstract

The time that it takes an occupant population to reach safety when descending a stairwell during building evacuations is typically described by measureable engineering variables such as stairwell geometry, speed, density, and pre-evacuation delay. In turn, engineering models of building evacuation use these variables to predict the performance of egress systems for uilding design, emergency planning, or event reconstruction. As part of a program to better understand occupant movement and behavior during building emergencies, the Engineering Laboratory at the National Institute of Standards and Technology (NIST) has been collecting stairwell movement data during fire drill evacuations of office and residential buildings. These data collections are intended to provide a better understanding of this principal building egress feature and develop a technical foundation for future codes and standards requirements. NIST has collected fire drill evacuation data in 14 buildings ranging from six to 62 stories in height that have included a range of stairwell widths and occupant densities. While average movement speeds in the current study of 0.47 m/s ± 0.17 m/s are observed to be quite similar to the range of literature values, local movement speeds as occupants traverse down the stairwell are seen to vary widely within a given stairwell, ranging from 0.05 m/s to 1.26 m/s. These data should provide confirmation of the adequacy of existing literature values typically used for occupant movement speeds and provide updated data for future analyses.
Citation
Technical Note (NIST TN) - 1839
Report Number
1839

Keywords

Disabled, egress, evacuation, evacuation modeling, fire safety, human behavior, mobility impairments

Citation

Kuligowski, E. , Peacock, R. , Reneke, P. , Wiess, E. , Averill, J. , Hagwood, R. , Ronchi, E. , Hoskins, B. and Spearpoint, M. (2014), Movement on Stairs During Building Evacuations, Technical Note (NIST TN), National Institute of Standards and Technology, Gaithersburg, MD, [online], https://doi.org/10.6028/NIST.TN.1839 (Accessed March 18, 2024)
Created September 24, 2014, Updated October 12, 2021