Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Large Area YBa2Cu3O7-x Bolometers on Si Substrates

Published

Author(s)

Leila R. Vale, Ronald H. Ono, Donald G. McDonald, Robert J. Phelan

Abstract

We have developed YBa2Cu3O7-x (YBCO) thermometers for large-area (4 mm x 4 mm) electrical substitution bolometers. We passivated the YBCO with a thin Au layer and demonstrated a noise equivalent temperature of 4 nK Hz-1/2. We then used a resistor layer of NiCr alloy deposited directly on the thermometer to perform optical measurements of the bolometer in the cryostat. Optical measurements show an electrical noise equivalent power of 87 pW Hz-1/2 with a large thermal conductance of 1.87 x 10-3 W K-1. these thermometers may be used as a real-time measurement radiometer.
Proceedings Title
Proc., 7th Intl. Superconductive Electronics Conf. (ISEC)
Issue
2
Conference Dates
June 21-25, 2099
Conference Location
Berkeley, CA, USA

Keywords

noise equivalent temperature, Yba<sub>2</sub>Cu<sub>3</sub>O<sub>7-x</sub> (YBCO) Thermometers

Citation

Vale, L. , Ono, R. , McDonald, D. and Phelan, R. (1999), Large Area YBa<sub>2</sub>Cu<sub>3</sub>O<sub>7-x</sub> Bolometers on Si Substrates, Proc., 7th Intl. Superconductive Electronics Conf. (ISEC), Berkeley, CA, USA (Accessed March 28, 2024)
Created May 31, 1999, Updated October 12, 2021